B+K precision 2510B Series User Manual page 90

Handheld digital storage oscilloscopes
Table of Contents

Advertisement

a. Press the
b. Press the
The threshold voltage level is for decoding, and it will be regard as the trigger voltage level
when set the trigger type to serial.
c. Press the first
7. Set MOSI:
a. Press the
b. Press the
The threshold voltage level is for decoding, and it will be regard as the trigger voltage level
when set the trigger type to serial.
c. Press the first
8. Set CS:
a. Press the
b. Press the
c. Press the
The threshold voltage level is for decoding, and it will be regard as the trigger voltage level
when set the trigger type to serial.
CS Type
~CS
CS
CLK Timeout
and select the channel connected to the SPI MISO signal.
softkey to set the SPI data signal's threshold.
softkey to return to the SPI signal menu.
and select the channel connected to the SPI MOSI signal.
softkey to set the SPI data signal's threshold.
softkey to return to the SPI signal menu.
softkey to select the chip select type.
and select the channel connected to the SPI CS signal.
softkey to set the SPI data signal's threshold.
low voltage level of CS signal is available
high voltage level of CS signal is available.
If the time between two edges of clock signal is less than (or equal to) the
timeout value, the signal between the two edges is treated as a frame.
The range of clock timeout is 100ns-5ms. This setting is suitable for case
where CS signal is not connected, or the number of oscilloscope channels
is insufficient.
Table 6.1 CS Types
Serial Trigger and Decode
Description
90

Advertisement

Table of Contents
loading

This manual is also suitable for:

2516b2511b2515b2512b

Table of Contents