The decoding result frames are presented as follows:
Arbitration field is displayed in frame
Control field is displayed in frame
Data field is displayed in frame
CRC field is displayed in frame
In cases where there is insufficient space on the display to show the complete content of a frame,
some of the content may be hidden, the indicator
The decoding list result are presented as follows:
Time: Thehorizontal displacement between current frame and trigger position.
Type: The type of frames, "D" represents data frame, "R" represents remote frame.
ID: The ID of frames, the oscilloscope can automatically detect the length of frame's id (11 bits or 27
bits).
Length: The length of the data field.
Data: The value of the data field.
CRC: The value of CRC (Cyclic Redundancy Check) field.
ACK: Acknowledgement bit.
Serial Trigger and Decode
will be provided.