Symptom
RMI or RMI-Q error LED
lit during probing cycle.
7.4
RMI or RMI-Q low
battery LED lit.
Reduced range.
Probe fails to switch off.
Probe goes into Trigger
Logic™ configuration
mode and cannot be
reset.
Cause
Probe not switched on or probe
timed out.
Probe out of range.
Dead batteries.
RMP40 and RMI or RMI-Q are
not partnered.
Probe selection error.
0.5 second turn-on error.
Low batteries.
Local radio interference.
Incorrect switch-off method
configured.
No RMI or RMI-Q "start/stop"
signal (radio on method only).
Probe in timeout mode and
placed in tool magazine and
being triggered by movement.
Incorrect spin speed (spin switch
on only).
Probe was triggered when
batteries were inserted.
Action
Change setting. Review switch-off
method.
Check position of RMI or RMI-Q,
see operating envelope.
Fit new batteries.
Partner RMP40 with RMI or
RMI-Q.
Verify that one RMP is working
and is correctly selected on the
RMI or RMI-Q.
Ensure that all RMPs are "Q"
marked probes, or change the
RMI-Q turn-on time to 1 second.
Change batteries soon.
Identify and remove.
Check configuration and alter as
required.
Check RMI or RMI-Q for green
start LED.
Use shorter timeout setting or use
different switch-off method.
Check spin speed.
Do not touch the stylus or stylus
mounting face during battery
insertion.