Multiple probe mode (omitted for "radio on")
see "Multiple probe mode settings" to view all 16 choices
Mode off
Machine 1
If no changes are made in "Multiple probe mode", then deflecting
the stylus for more than 4 seconds will return the probe settings
to "Switch-on method". If "Multiple probe mode" is selected,
proceed to "Acquisition mode" to repartner one probe with the
NOTE: If using mutiple probe mode, refer to
the RMI radio machine interface installation
guide (Renishaw part no. H-4113-8554) or the
RMI-Q radio machine interface installation guide
(Renishaw part no. H-5687-8504).
NOTE: To partner an RMP40 with an RMI please
see "RMP40 – RMI partnership". Once acquisition
has been successful, the RMP40 will revert to
"Acquisition mode off".
Acquisition mode
Acquisition mode off
Stop triggering here, unless "Multiple probe
mode" is required, in which case deflect the
stylus for more than 4 seconds.
Mode on
Machine 2
RMI or RMI-Q.
Acquisition mode
Acquisition mode off
Return to "Switch-on method"
NOTE: Further probes used require the same
multiple probe mode setting, but do not need to
be partnered with the RMI or RMI-Q.
NOTE: To partner an RMP40 with an RMI-Q
please see "RMP40 – RMI-Q partnership". Once
acquisition has been successful, the RMP40 will
revert to "Acquisition mode off".
Acquisition mode on
Machine 16
Acquisition mode on
4.5
New settings
complete