RMP40 installation guide

Operating mode

LEDs
flashing
green
4.8
Probe status LEDs
LED colour
Flashing green
Flashing red
Flashing green and blue
Flashing red and blue
Constant red
Flashing red
or
Flashing red and green
or
Sequence when batteries are inserted
NOTE: Due to the nature of lithium-thionyl
chloride batteries, if a "low battery" LED warning is
ignored, it is possible for the following sequence of
events to occur:
1.
When the probe is active, the batteries
discharge until battery power becomes too
low for the probe to operate correctly.
2.
The probe stops functioning, but then
reactivates as the batteries recover
sufficiently to provide the probe with power.
3.
The probe begins to run through the LED
review sequence (see "Reviewing the probe
settings").
LEDs
flashing
red
X/Y
Probe seated in operating mode
Probe triggered in operating mode
Probe seated in operating mode – low battery
Probe triggered in operating mode – low battery
Battery dead
Unsuitable battery
Probe status
4.
Again, the batteries discharge and the probe
ceases to function.
5.
Again, the batteries recover sufficiently
to provide the probe with power, and the
sequence repeats itself.
LEDs
flashing
red
Z
Graphic hint