Message
Description
Files too big
Handset software download files are
incorrect or corrupted.
Flash config error
Handset internal configuration is corrupt.
Initializing ...
The handset is performing power on
initialization.
Internal Err. # #
The handset has detected a fault from
which it cannot recover.
OE = Error while writing the Flash (return
handset to factory).
OF = No functional code (contact
SpectraLink Technical Support).
Multiple GW Reg
y...y = Gateway IP address
yyy.yyy.yyy.yyy
Handset received responses from
multiple gateways; displays IP address of
one responding gateway.
Must Upgrade SW!
Handset software is incompatible with
hardware.
Net Busy
x...x = AP MAC address
xxxxxxxxxxxx
Handset cannot obtain sufficient
bandwidth to support a call; displays
MAC of failing AP.
No DHCP Server
Handset is unable to contact the DHCP
server.
No ESSID
Attempted to run site survey application
without an ESSID set.
No Func Code
Handset software download files are
incorrect or corrupted.
No GW Response
y...y = Gateway IP address
yyy.yyy.yyy.yyy
Handset has lost contact with the NetLink
Telephony Gateway.
Handset cannot find an NetLink
Telephony Gateway.
Handset not registered on NetLink
Telephony Gateway.
NetLink Telephony Gateway is not
working
No LAN connection at the AP or NetLink
Telephony Gateway.
PN: 72-1065-09-H.doc
Configuration and Administration–NetLink e340,/h340/ i640 Wireless Telephone
NetLink Telephony Gateway and SpectraLink Radio Protocol
Action
Download new software from the SpectraLink
site per section 8
Perform "Restore Defaults" operation via
administrator menus [or reprogram with
Configuration Cradle].
None. This is informational only.
Record the error code so it can be reported.
Turn the handset off then on again.
If error persists, try registering a different
handset to this telephone port.
If error still persists, contact SpectraLink
Technical Support and report the error.
Check each NetLink Telephony Gateway for
the handset's MAC address on the Telephone
Line Configuration screen. Delete any
duplicate entries leaving only one entry on the
correct Telephone Gateway and port for this
handset.
Download new software from the SpectraLink
site per section 8
Try the call again later.
Check that DNCP is operational and
connected to WLAN or use Static IP
configuration in the handset.
Let handset come completely up.
Statically configure an ESSID in the Admin
menu.
Reconfigure the handset to gain access to the
WLAN and download new code.
Verify that the NetLink Telephony Gateway is
properly configured.
Verify that the NetLink Telephony Gateway is
powered on. If so, follow standard NetLink
Telephony Gateway troubleshooting
procedures.
Verify NetLink Telephony Gateway connection
to LAN and all APs.