Static Gobowheel, Rotating Gobowheel and Colorwheel
Rotating Gobo-wheel
6
5
4
Color-wheel
Troubleshooting
No Light
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps
below in sequence until a solution is found. Once the unit operates properly, do not carry out following
steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect three potential problem areas: the power supply, the lamp, the fuse.
1. Power supply. Check that the unit is plugged into an appropriate power supply.
2. The LEDs. Return the Indigo 5500 LED to your Showtec dealer.
3. The fuse. Replace the fuse. See page 27 for replacing the fuse.
1
2
3
Fig. 10
Fig. 12
Static Gobo-wheel
6
29
7
1
2
5
3
4
Fig. 11