  • Page 1 MANUAL ENGLISH ACT Profile 50 WW Order code: 34030 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2: Table Of Contents

    ACT Profile 50 WW Table of contents Warning ....................................2 Safety Instructions ................................. 2 Operating Determinations ............................4 Rigging .................................... 5 Angle Adjustment ..............................5 Connection with the Mains ............................6 Return Procedure ................................6 Claims ....................................6 Description of the Device ..............................7 Features ..................................
  • Page 3: Warning

    Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture will be returned in the original factory box and packing. Your shipment includes: ● Showtec ACT Profile 50 WW ● 5 x metal gobos ● Color frame ●...
  • Page 4 ● If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
  • Page 5: Operating Determinations

    ACT Profile 50 WW ● This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth. ● Repairs, servicing and electric connection must be carried out by a qualified technician. ● WARRANTY: Till one year after date of purchase.
  • Page 6: Rigging

    ACT Profile 50 WW Rigging Please follow the European and national guidelines concerning rigging, trussing and all other safety issues. Do not attempt the installation yourself! Always let the installation be carried out by an authorized dealer! Procedure: ● If the device is lowered from the ceiling or high joists, professional trussing systems have to be used.
  • Page 7: Connection With The Mains

    ACT Profile 50 WW Connection with the Mains Connect the device to the mains with the power plug. Always check if the right color cable is connected to the right place. International EU Cable UK Cable US Cable BROWN YELLOW/COPPER...
  • Page 8: Description Of The Device

    Included gobo set The ACT Profile 50 WW is delivered with a set of 5 metal gobos. Refer to Gobo Replacement on page 11 and Changing the Gobo on page 12 for more information about how to change the gobo.
  • Page 9: Overview

    ACT Profile 50 WW Overview Fig. 02 01) Mounting bracket 02) Safety eye 03) 4 x Framing shutters 04) 3 x Color frame holders 05) Lens 06) Color frame clip 07) Spring-loaded screw Fig. 03 08) Gobo holder 09) 2 x Cover plate thumbscrews...
  • Page 10: Backside

    21) Manual dimmer control Installation Remove all packing materials from the ACT Profile 50 WW. Check if all foam and plastic padding is removed. Connect all cables. Do not supply power before the whole system is set up and connected properly.
  • Page 11: Beam Angle Adjustment

    Fig. 05 Color Frame Positioning The ACT Profile 50 WW is delivered with a color frame. You can insert a color gel or a diffusion filter into the color frame. Make sure that the color frame is locked in position with the color frame clip before using the ACT Profile 50 WW.
  • Page 12: Beam Shaping

    Fig. 09 Gobo Replacement The ACT Profile 50 WW is delivered with a gobo holder and a set of 5 metal gobos. You can order an additional gobo set of 5 metal gobos with seasonal patterns (order code 34050). To replace the gobo, follow the steps below: 01) Loosen the two cover plate thumbscrews (09) (see Fig.
  • Page 13: Changing The Gobo

    ACT Profile 50 WW Changing the Gobo 01) Remove the retaining ring from the gobo holder (08) with needle-nose pliers or a similar sharp tool. 02) Change the metal gobo. Make sure that the painted (black) side of the gobo is facing upwards as shown on Fig.
  • Page 14: Control Modes

    ACT Profile 50 WW Control Modes There are 2 modes: ● Manual control ● DMX-512 (1CH, 2CH) One ACT Profile (Manual Control) 01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation.
  • Page 15: Multiple Act Profiles (Dmx Control)

    ACT Profile 50 WW Multiple ACT Profiles (DMX Control) 01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Secure the device with a safety cable (order code 70140 / 70141).
  • Page 16: Fixture Linking

    ACT Profile 50 WW Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX-512. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
  • Page 17: Control Panel

    ACT Profile 50 WW Control Panel A) OLED display B) ENTER button C) DOWN button D) UP button E) MENU button Fig. 19 DMX Addressing The control panel on the back side of the fixture allows you to assign the fixture a DMX address, which is the first channel with which the ACT Profile will respond to a DMX controller.
  • Page 18: Main Menu Overview

    ACT Profile 50 WW Main Menu Overview Order code: 34030...
  • Page 19: Start-Up

    ACT Profile 50 WW Start-up Upon start-up the display will show a splash screen with the name of the device: Immediately afterwards the display will show the start screen. The start screen provides information about the current control mode of the device and the temperature of the LEDs.
  • Page 20: Dmx Address

    ACT Profile 50 WW 1.1 DMX Address In this pop-up submenu you can set the starting DMX address of the device. 01) Press the UP/DOWN buttons to select the starting DMX address of the device. The selection range is between 1 and 512.
  • Page 21: Manual Settings

    ACT Profile 50 WW 2. Manual Settings In this menu you can select how the device will be operated manually. 01) Press the ENTER button to open the pop-up submenu for the manual mode settings. 02) Press the UP/DOWN buttons to select one of the following 2 options: ●...
  • Page 22: Fixture Test

    ACT Profile 50 WW 02) Press the ENTER button to confirm the selection and open the pop-up submenu where you can adjust the settings. 03) Press the UP/DOWN buttons to select the desired setting. 04) Press the ENTER button to confirm the selection.
  • Page 23: Special Functions

    ACT Profile 50 WW 7. Special Functions In this menu you can reset the device’s settings to the default factory settings. 01) Press the ENTER button to open the pop-up submenu for the factory settings: 02) Press the UP/DOWN buttons to choose between NO and YES. If you choose YES, the device’s settings will be reset to the default factory settings.
  • Page 24: Maintenance

    04) The electric power supply cables must not show any damages or material fatigue. The ACT Profile 50 WW requires almost no maintenance. However, you should keep the unit clean. Otherwise, the fixture’s light output will be significantly reduced. Disconnect the mains power supply and then wipe the cover with a damp cloth.
  • Page 25 ACT Profile 50 WW Problem Probable cause(s) Solution ● Check if power is switched on and One or more fixtures No power to the fixture cables are plugged in do not function at all Primary fuse blown ● Replace fuse...
  • Page 26: Product Specifications

    ACT Profile 50 WW Product Specifications Model: Showtec ACT Profile 50 WW Input voltage: 100–240 V AC, 50/60 Hz Power consumption: 57 W Fuse: T1 AL/250 V AC Dimensions: 411 x 267 x 170,5 mm (L x W x H)