11 Maintenance
11.4

Cleaning the machine

WARNING
Use of improper cleaning agents may lead to fire or explosion.
Wacker Neuson recommends cleaning the machine after each use for long, trouble-free running times.
The following points must be observed and complied with:
Do not use high pressure washers for cleaning – danger from electric shock.
Only use clean water for cleaning – wipe machine dry with a cloth.
11.4.1
Cleaning the Bodyguard®
Do not clean the Bodyguard® with high pressure l or steam cleaners!
Do not exert any hammer blows on the Bodyguard® to remove contaminations!
Do not submerge the Bodyguard® in water!
Do not use any fuels or solvents.Explosion hazard!
11.5

Lubricate machine

WARNING
Excessive grease can conduct electricity.
Injuries from electrocution.
Item
Designation
1
Tapered zerk fitting
To achieve long, error-free running times for this machine, Wacker-Neuson recommends lubricating it
periodically.
NOTE
Over-greasing alters machine behaviour to the point of failure.
The following points must be observed and complied with:
1. Remove any dirt around the zerk fitting.
2. Place filled manual lever-type grease gun (DIN 1283) onto the lubrication nipple and operate
approximately once or twice (1.0-2.0 cm3) per lubrication nipple.
3. Wipe the area around the zerk fitting with a clean cloth.
29
Do not use gasoline or any other solvents to clean the machine.
Wipe off excessive grease.