Wacker Neuson AR Operator's Manual page 41

External vibrator
Table of Contents

Advertisement

17 Technical data
17.1.1
Extension cable
WARNING
Warning about voltage.
Serious injuries from electric shock.
The following points must be observed:
Only use permitted extension cables.
Refer to nameplate for details of type designation and voltage of this machine.
Refer to the following table for the required cross-section area.
Machine type
AR43/3/230 v
AR43/3/400
AR43/6/042
AR43/6/250
Machine type
AR43/3/230 v
AR43/3/400
AR43/6/042
AR43/6/250
41
Check power cable and extension cable for signs of damage.
Only use extension cables for which grounded conductors are connected to the plug
and the coupling (only for machines of protection class I + III, see chapter "Technical
data").
Voltage
[V]
230 1~
400 3~
42 3~
250 3~
Voltage
[V]
230 3~
400 3~
42 3~
250 3~
Extension
[m] (ft)
< 150 (492.1)
< 150 (492.1)
< 10 (32.8)
< 17 (55.8)
< 27 (88.6)
< 39 (128.0)
< 61 (200.1)
< 150 (492.1)
Extension
[m] (ft)
< 150
< 150
< 9
< 14
< 22
< 34
< 52
< 150
Cross-section area of
cable
2
[mm
]
1.5
1.5
1.5
2.5
4
6
10
1.5
Cross-section area of
cable
[AWG]
16
16
16
14
12
10
8
16
100_0102_td_0007.fm

Advertisement

Table of Contents
loading

Table of Contents