Wacker Neuson AR Operator's Manual page 36

External vibrator
Table of Contents

Advertisement

15.1.1
Extension cable
WARNING
Warning about voltage.
Serious injuries from electric shock.
The following points must be observed:
Only use permitted extension cables.
Refer to nameplate for details of type designation and voltage of this machine.
Refer to the following table for the required cross-section area.
Machine type
AR26/3/230 w
AR26/3/400
AR26/3.6/230 US
AR26/6/042
AR26/6/042 cs
AR26/6/042 3.5kN
AR26/6/250
Machine type
AR26/3/230 w
AR26/3/400
AR26/3.6/230 US
AR26/6/042
AR26/6/042 cs
AR26/6/042 3.5kN
AR26/6/250
100_0102_td_0002.fm
Check power cable and extension cable for signs of damage.
Only use extension cables for which grounded conductors are connected to the plug
and the coupling (only for machines of protection class I + III, see chapter "Technical
data").
Voltage
[V]
230 1~
400 3~
230 3~
42 3~
250 3~
Voltage
[V]
230 1~
400 3~
230 3~
42 3~
250 3~
Extension
[m] (ft)
< 150 (492.1)
< 150 (492.1)
< 150 (492.1)
< 16 (52.5)
< 26 (85.3)
< 40 (131.2)
< 58 (190.3)
< 150 (492.1)
Extension
[m] (ft)
< 150 (492.1)
< 150 (492.1)
< 150 (492.1)
< 14 (45.9)
< 21 (68.9)
< 33 (108.3)
< 51 (167.3)
< 150 (492.1)
15 Technical data
Cross-section area of
cable
2
[mm
]
1.0
1.5
1.5
1.5
2.5
4
6
1.5
Cross-section area of
cable
[AWG]
16
16
16
16
14
12
10
16
36