Wacker Neuson AR Operator's Manual page 53

External vibrator
Table of Contents

Advertisement

20 Technical data
Designation
Item no.
Rated current
Rated voltage
Rated frequency
Rated output
Phases
Centrifugal force
Vibrations
Centrifugal force max.
Length
Width
Height
Weight
Motor type
Class rating
Protection class *
Storage temperature range
Operating temperature
range
Housing external
temperature
Sound pressure level L
Standard
*
Only guaranteed with a Wacker Neuson power cable.
**
Measured at distance of 1 m (3.2 ft).
53
Unit
A
V
Hz
kW
~
kN
rpm
Hz
kN
mm (in)
mm (in)
mm (in)
kg (lb)
°C (°F)
°C (°F)
°C (°F)
**
dB(A)
pA
AR75/6/042
5000007794
32,00
42
200
2,00
3
14,05
6,000
100
26,56
330 (13.0)
218 (8.6)
218 (8.6)
26.80 (59.1)
Induction motor
lll
IP67
-30 – +70
(-22 – +158)
-10 – +50
(+14 – +122)
80 (176)
79
EN ISO 11201, EN 12649
AR75/6/250
5000007797
7,50
250
200
2,50
3
14,05
6,000
100
26,56
330 (13.0)
218 (8.6)
218 (8.6)
26.80 (59.1)
l
IP67
-30 – +70
(-22 – +158)
-10 – +50
(+14 – +122)
80 (176)
79
100_0102_td_0008.fm

Advertisement

Table of Contents
loading

Table of Contents