7 OPTION (Setting Code 38)
- Operation instruction timing (using special operation instruction bits)
Operation instructions can also be given by using the bits from RY0010 to RY0014.
The R/W may be either ON or OFF.
When tare subtraction is taken as an example, the operation is performed at the tare subtraction
edge input.
Pulse width should be ON more than 20ms.
Chapter
7
- Reading out of set value timing
To read set values, turn the R/W ON.
Read the reading data area after making sure that the response has turned ON.
64
64
Request
(RY0002)
Response
(RX0002)
R/W
(RY0003)
Set value
(RWw0004)
to
(RWw0005)
Code No.
(RWw0006)
R/W (response)
(RX0003)
Code No. (response)
(RWr0006)
Tare subtraction
(RY0012)
Request
(RY0002)
Response
(RX0002)
R/W
(RY0003)
Code No.
(RWw0006)
R/W (response)
(RX0003)
Code No. (response)
(RWr0006)
Reading out of set value data
(RWr0004)
to
(RWr0005)
20msec or more