Upper/Lower Limit Comparison Mode (Setting Code 28); Comparison Inhibit Time/ Judging Time/ Complete Output Time (Setting Code 10 To 12) - Unipulse F160 Operation Manual

Weighing controller
Table of Contents

Advertisement

5 FUNCTIONS

■Upper/Lower Limit Comparison Mode (Setting Code 28)

■Comparison Inhibit Time/ Judging Time/ Complete Output Time
(Setting Code 10 to 12)
Comparison inhibit time/ Judging time
These functions inhibit comparison for a fixed period so that control and judgment will not be
operated inappropriately due to mechanical vibrations caused by opening and closing of valves.
Chapter
5
Complete output time
Set the length of the complete signal (complete relay) to be output when weighing is completed.
Setting range and code No. of each set value
36
36
Setting/ 0: Continuous comparison
1: Comparison when the external judgment input is ON
Weight
Final - Compensation
Final - Set Point 2
Final - Set Point 1
0
Weight
Final
Final - Compensation
Final - Set Point 2
Final - Set Point 1
Near zero
0
Stable
Complete
Complete
output time
Set value
Setting range
Comparison
inhibit time
Judging time
(0.00 to 9.99 sec.)
Complete
output time
Judging time
Comparison inhibit time
ON
ON
Complete output time
Initial value
50
000 to 999
150
300
Over
Under
Time
Code No.
10
11
12

Advertisement

Table of Contents
loading

Table of Contents