Sequence With Adjust Feeding Valid - Unipulse F160 Operation Manual

Weighing controller
Table of Contents

Advertisement

■Sequence with Adjust Feeding Valid

● Set adjust feeding ON/OFF in the sequence mode of setting code 51 to ON.
● The complete signal output timing depends on the setting of the complete output mode of setting
code 26.
● Over/Under comparisons are made, holding the weight value, when the complete output is ON,
deregarding the setting of Over/Under comparison mode of setting code 27.
● Upper/Lower limit comparisons are always made deregarding the setting of the Upper/Lower
limit comparison mode of setting code 28.
t1: Comparison inhibit time; comparison inhibit time of setting code 10
t2: Judging time; judging time of setting code 11
t3: Complete output time; complete output time of setting code 12
t4: Adjust feeding time; adjust feeding time of setting code 13
Adjust feeding time (Setting code 13)
S
et the adjust feeding time.
Setting range/ 000 to 999
Adjust feeding at the sequence mode (Setting code 51)
Determines whether adjust feeding is valid or invalid.
Setting/ 0: Invalid  1: Valid
41
Start
ON
OFF
Stop
SP1
ON
SP2
ON
SP3
ON
Complete
Judgment (Over or Go)
Comparison inhibit time
Judging time
Adjust feeding time
Complete output time
t1
t1
t2
t4
Initial value/ 100
5 FUNCTIONS
ON
ON
t2
t3
Hold
41