Sequence Control
■Normal Sequence (With Judgment)
Final - Compensation
Final - Set Point 2
Final - Set Point 1
● The complete signal output timing depends on the setting of the complete output mode of setting
code 26.
● Over/Under comparisons are made, holding the weight value, when the complete output is ON,
deregarding the setting of Over/Uunder comparison mode of setting code 27.
● Upper/Lower limit comparisons are always made deregarding the setting of the Upper/Lower
limit comparison mode of setting code 28.
t1: Comparison inhibit time; comparison inhibit time of setting code 10
t2: Judging time; judging time of setting code 11
t3: Complete output time; complete output time of setting code 12
39
Weight
Final
Near zero
0
Start
ON
Stop
SP1
ON
SP2
ON
SP3
ON
Complete
Judgment (Over or Go or Under)
Comparison inhibit time
Judging time
Complete output time
OFF
t1
t1
5 FUNCTIONS
Over
Under
Time
ON
ON
t2
t3
Hold