Processing Solutions; Preparation - Kodak M35M X-Omat Operator's Manual

Table of Contents

Advertisement

Section 3: Processing Solutions

Preparation

Processing Tanks with the Splash Guard
Figure 9
and the Drip Tray
DRIP TRAY
Draining the Tanks
Warning
• Drains must be made of chemically resistant, non-corrosive material. Use PVC or the equivalent.
• The drain must have a minimum diameter of 7.6 cm (3 in.) and be free of obstruction.
• Drain service must comply with all local codes.
Caution
• Drain only one Tank at a time.
• Make certain that all drain materials and fluids comply with local, state, and federal regulations.
981799 - 09JUL98
SPLASH GUARD
H112_0015ACA
H112_0015AC
Use only qualified service personnel to perform
all necessary adjustments and procedures.
Caution
Avoid contamination of the processing solutions.
• To avoid spilling solutions from one tank into
the next one, use the Splash Guard between the
developer and fixer Tanks.
• Slowly install or remove the Racks.
• Use the Drip Tray when moving Racks to or
from the PROCESSOR.
[1] Mix the volume of processing solution required in
the correct Replenishment Tank. Use the
instructions packed with the chemicals to mix the
solution.
Important
Do not mix more than a 2-week supply for
Replenishment Tanks with floatation lids.
[2] Remove the Crossover Assembly and the Rack
from the Tank that is to be filled.

Processing Solutions

9

Advertisement

Table of Contents
loading

This manual is also suitable for:

M35a-m x-omat

Table of Contents