Connecting To Uninterruptible Power Supply (Ups) - NEC EXP805 User Manual

Hide thumbs Also See for EXP805:
Table of Contents

Advertisement

Chapter 2 Preparations
Note the following precautions to connect cables.
When the device is not Plug and Play device, turn off the server and devices to be connected before
connecting.
If connecting any peripheral device and its interface cable made by other companies (a third party), contact
your sales representative to check if they can be used with the server beforehand.
Fix the power cord or interface cable with cable ties.
Make sure that no pressure is applied on the plug of power cord.

Connecting to Uninterruptible Power Supply (UPS)

To connect the power cord of the server to a UPS, use the connector output on the rear of the UPS. For details,
refer to the manual supplied with the UPS.
Example
Option slot
Input connector
(NEMA5-15P)
When the power cord is connected to a UPS, change the settings from System Utility in order to link the server
with the power supply from the UPS.
To change the settings, select System Configuration > BIOS/Platform Configuration (RBSU) > System
Options > Server Availability > Automatic Power-On. Select Always Power On to perform automatic
operations by using the UPS. For details, see Chapter 3 (2. Description on System Utility)).
When connecting UPS to a serial port, set the following item to 'Disabled'.
1.
System Configuration > BIOS/Platform Configuration (RBSU) > System Options > Serial Port Options >
BIOS Serial Console and EMS > BIOS Serial Console Port → 'Disabled'
2.
System Configuration > BMC Configuration Utility > Setting Options > Serial CLI Status → 'Disabled'
220
Universal Serial Bus (USB)
Overload protection
reset button
Computer interface port (COM)
Voltage sensitivity setting button
Express5800/R120h-2M (2nd-Gen) User's Guide
Connector outputs
TVSS device connector
2. Installation and Connection