Christie CineLife+ RGB PLF Installation And Setup Manual page 42

Table of Contents

Advertisement

2. Using the provided funnel, fill the chiller reservoir with the required coolant (Propylene Glycol
P/N: 163-130105-XX).
3. Start the chiller and allow the coolant lines to fill.
4. Check the coolant level in the reservoir and top up the coolant as required.
For detailed information on operating and maintaining the chiller, refer to the product
documentation provided by the chiller manufacturer.
5. On the projector touch panel, select Laser Settings > Laser Power/LiteLOC Setup, and
under Chiller Setpoint, set the required temperature for the chiller.
The recommended chiller set point temperature is 24°C.
6. Verify that coolant is flowing in the correct direction and that there are no leaks in the system.
7. Ensure the chiller communication cable between the projector and the chiller is connected
correctly.
To avoid thermal shutdown conditions in dual projector installations, Christie recommends
running each chiller and its attached projector separately, with light on, to confirm that chiller
communication cables are not cross-connected relative to the coolant lines.
Related information
Setting the chiller setpoint (on page 43)
Creating a new laser file for CP4440-RGB and CP4450-RGB (on page 60)
CineLife+ RGB PLF Installation and Setup Guide–CP4440-RGB, CP4450-RGB