Raid Controller Card; Network; Loms - xFusion Digital Technologies FusionServer CH242 V5 Manual

Table of Contents

Advertisement

FusionServer CH242 V5 Compute Node
Technical White Paper
Table 5-8 NVMe drive indicators (VMD disabled)
Activity Indicator
(Green)
Off
Steady on
Blinking at 2 Hz
Off
Off
Steady on/Off

5.4.4 RAID Controller Card

The RAID controller card supports RAID configuration, RAID level migration, and drive
roaming.

5.5 Network

5.5.1 LOMs

The LOM is a network interface module (X722) integrated in the PCH. It can be connected to
an I/O module (switch module). The LOM provides two 10GE network ports for connecting
to the Base network ports of the switch modules in slots 2X and 3X. The LOM supports Wake
on LAN (WOL) and PXE functions.
2022-08-12
Fault Indicator
(Yellow)
Off
Off
Off
Blinking at 2 Hz
Blinking at 0.5 Hz
Steady on
Contact your local sales representative or use the
components to be used.
For details about the RAID controller card, see
Guide.
5 Hardware Description
Description
The NVMe drive cannot be detected.
The NVMe drive is working properly.
Data is being read from or written to the
NVMe drive.
The NVMe drive is being located or
hot-swapped.
The hot removal process is complete, and
the NVMe drive is removable.
The NVMe drive is faulty.
Compatibility Checker
V5 Server RAID Controller Card User
to determine the
29

Advertisement

Table of Contents
loading

Table of Contents