  • Page 1 FusionServer CX5200 V5 Server Technical White Paper Issue Date 2023-12-13 xFusion Digital Technologies Co., Ltd.
  • Page 2 Notice In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technologies Co., Ltd.
  • Page 3: About This Document

    NOTICE is used to address practices not related to personal injury. Supplements the important information in the main text. NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 4 2023-12-13 ● Added 11 Waste Product Recycling. ● Updated Certifications. ● Updated A.4 Nameplate Model. 2022-11-30 Added RAID controller card related content. 2022-09-15 This issue is the first official release. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 5: Table Of Contents

    5.4.1.6 Memory Protection Technologies......................23 5.5 Storage..............................23 5.5.1 Drive Configurations ..........................24 5.5.2 Drive Numbering.............................24 5.5.3 Drive Indicators............................24 5.6 Network..............................25 5.6.1 LOMs..............................25 5.7 I/O Expansion............................28 5.7.1 PCIe Cards............................. 28 Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 6 A.3 Operating Temperature Limitations......................59 A.4 Nameplate Model............................59 A.5 RAS Features............................59 A.6 Sensor List..............................61 B Glossary......................... 67 B.1 A-E................................67 B.2 F-J................................67 B.3 K-O................................68 B.4 P-T................................68 B.5 U-Z................................69 Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 7 FusionServer CX5200 V5 Server Technical White Paper Contents C Acronyms and Abbreviations..................70 C.1 A-E................................70 C.2 F-J................................71 C.3 K-O................................73 C.4 P-T................................73 C.5 U-Z................................75 Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 8: Overview

    Technical White Paper 1 Overview Overview FusionServer CX5200 V5 (CX5200 V5) is a heterogeneous computing server developed by xFusion to meet service requirements such as AI, HPC, cloud computing, and big data processing. It is applicable to AI inference, AI training, HPC heterogeneous computing, graphics rendering and other application requirements.
  • Page 9: Features

    AVX-512 doubles the width and number of data registers and the width of FMA units. – The Cascade Lake processors support Intel® Deep Learning Boost vector neural network instructions (VNNI) to improve the performance of deep learning applications. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 10 Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer overflow attacks when working with a supported OS. ● Intel Trusted Execution Technology enhances security using hardware-based defense against malicious software attacks, allowing applications to run independently. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 11 Low-voltage Intel Xeon Scalable processors consume less energy, ideally suited for data centers and telecommunications environments constrained by power and thermal limitations. ● SSDs consume 80% less power than HDDs. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 12: Physical Structure

    Figure 3-1 CX5200 V5 physical structure I/O adapter board PCIe card Chassis PSU backplane Air duct Fan adapter board Drive backplane Fan module Drive CPU heat sink Mainboard Memory TPM/TCM Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 13: Logical Structure

    The server provides low-speed I/O ports, such as the VGA port, USB 3.0 ports, and USB 2.0 ports. ● The server provides four LOM ports, including two 10GE optical ports and two GE electrical ports. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 14: Hardware Description

    5.4 Memory 5.5 Storage 5.6 Network 5.7 I/O Expansion 5.8 PSUs 5.9 Fans 5.10 Boards 5.1 Front Panel 5.1.1 Appearance ● 8 x 2.5" SATA drive configuration Figure 5-1 Front view Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 15: Indicators And Buttons

    1 port 2 Connection status Connection status indicator for GE LOM port indicator for GE LOM port Fault diagnosis LED Health status indicator UID button/indicator Power button/indicator Fan indicator Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 16 6 seconds will forcibly power off the device. ● When the power indicator is steady yellow, you can press this button to power on the device. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 17 Fan indicator ● Off: The fan module is powered off. ● Blinking red: An alarm has been generated on the fan module. ● Steady green: The fan module is working properly. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 18: Ports

    NOTICE Before connecting an external USB device, check that the USB device functions properly. The server may operate abnormally if an abnormal USB device is connected. 5.2 Rear Panel Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 19: Appearance

    PCIe slot 1 PCIe slot 2 PCIe slot 3 PCIe slot 4 PCIe slot 5 PCIe slot 6 PCIe slot 7 PCIe slot 8 PCIe slot 9 PSU 2 PSU 1 Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 20: Indicators

    ● Blinking or steady blue: The device is being located. NOTE You can control the UID indicator state by pressing the UID button or running a command on the iBMC CLI. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 21 The possible causes of no power output are as follows: ● Power supply overtemperature protection ● Power output overcurrent or short-circuit ● Output overvoltage ● Short-circuit protection ● Device failure (excluding failure of all devices) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 22: Ports

    Table 5-4 Ports on the rear panel Port Type Quantity Description LOM port 10GE SFP 10GE LOM service port (optical) and GE service port 1000BASE-T (electrical). For details, see the 5.6.1 LOMs. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 23: Processor

    The server supports one or two processors. ● The same model of processors must be used in a server. ● Contact your local sales representative or use the Compatibility Checker determine the components to be used. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 24: Memory

    Figure 5-7 Processor positions 5.4 Memory 5.4.1 DDR4 Memory 5.4.1.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module. Figure 5-8 Memory identifier Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 25: Memory Subsystem Architecture

    CX5200 V5 provides 12 memory slots. Each CPU integrates six memory channels. Table 5-5 Memory channels Memory Channel Memory Slot CPU 1 A (primary) DIMM000(A) B (primary) DIMM010(B) C (primary) DIMM020(C) D (primary) DIMM030(D) E (primary) DIMM040(E) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 26: Memory Capatibility

    ▪ L processors: 4.5 TB/socket ▪ M processors: 2 TB/socket ▪ Other processors: 1 TB/socket ● The total memory capacity is the sum of the capacity of all DDR4 DIMMs. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 27: Dimm Installation Rules

    DIMM can reach 2666 MT/s only. Different CPUs possess different specifications, For details about the CPU parameters, see the Intel official website. 5.4.1.4 DIMM Installation Rules ● Observe the following when configuring DDR4 memory modules: Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 28: Memory Installation Positions

    CX5200 V5 supports up to 12 Double Data Rate 4 (DDR4) memory modules. To maximize the performance, it is recommended to use balanced memory configuration. NO TICE At least one DDR4 DIMM must be installed in the memory slots corresponding to CPU 1. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 29 FusionServer CX5200 V5 Server Technical White Paper 5 Hardware Description Figure 5-9 Memory slots Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 30: Memory Protection Technologies

    ● Memory thermal throttling ● Memory address parity protection ● Memory demand/patrol scrubbing ● Device tagging ● Data scrambling ● Adaptive double device data correction (ADDDC) ● ADDDC+1 5.5 Storage Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 31: Drive Configurations

    5.5.2 Drive Numbering ● 8 x 2.5" SATA drive configuration Figure 5-11 Drive numbering 5.5.3 Drive Indicators SATA Drive Indicators Figure 5-12 SATA drive indicators Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 32: Network

    Negotiatio Rate Supported Ports n Mode X722 10GE Auto- 10000M 10/100/100 optical negotiation port 10000 Mbit/s (full duplex) Auto- 1000M 10/100M electrical negotiation port 10000 Mbit/s (full duplex) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 33 WebUI. Figure 5-13 LOM port 10GE optical port (LOM 10GE optical port (LOM port 1) port 2) GE electrical port (LOM GE electrical port (LOM port 3) port 4) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 34 (LOM port 3) (LOM port 3) Data transmission status Connection status indicator indicator for the GE for the GE electrical port electrical port (LOM port 4) (LOM port 4) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 35: I/O Expansion

    IB cards at both ends of the network are the same. For details, contact technical support. ● A CX5200 V5 server configured with GPU cards cannot be transported with the GPU cards installed. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 36: Pcie Slots

    ● The server supports two PSUs. ● The server supports AC PSUs. ● The PSUs are hot-swappable. ● The server supports two PSUs in 1+1 redundancy or 2+0 non-redundancy mode. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 37: Fans

    The fan modules are hot-swappable. ● The server tolerates failure of a single fan. ● The fan speed can be adjusted. ● The same model of fan modules must be used in a server. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 38: Boards

    FusionServer CX5200 V5 Server Technical White Paper 5 Hardware Description Figure 5-17 Fan module positions 5.10 Boards Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 39: Mainboard

    CONN/J2) 10GE optical port (10GE TPM/TCM port (J55) PORT/J11615) SATA port (SATA CONN2/ SATA port (SATA CONN1/ J71) J67) RTC battery (U4042) Mini SAS HD port (mini- SAS PORTB/J84) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 40: Drive Backplane

    PSU backplane power PSU backplane power connector (PDB MISC connector (J11613/J11617/ CONN/J11620) J11618) 5.10.2 Drive Backplane ● 8 x 2.5" SATA drive backplane Figure 5-19 8 x 2.5" SATA drive backplane Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 41: I/O Adapter Board

    Mini-SAS HD connector Mini-SAS HD connector (PORT A/J28) (PORT B/J29) 5.10.3 I/O Adapter Board Figure 5-20 CX5200 V5 I/O adapter board VGA port (VGA CONN/J3) USB 3.0 port (USB 3.0 CONN/J2) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 42: Psu Backplane

    5 Hardware Description GE electrical port 2 (1GE GE electrical port 1 (1GE PORT2 CONN/J6) PORT1 CONN/J4) Management network port (BMC GE CONN/J5) 5.10.4 PSU Backplane Figure 5-21 CX5200 V5 PSU backplane Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 43: Fan Adapter Board

    Signal cable connector (J3) 5.10.5 Fan Adapter Board Figure 5-22 CX5200 V5 fan adapter board Fan connector Power connector (POWER CONNECTOR/J1) Fan adapter board signal Fan adapter board latch connector (CONTROL CONNECTOR/J7) Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 44: Product Specifications

    ● Min. 1.375 MB L3 cache per core ● Max. 205 W thermal design power (TDP) NOTE The preceding information is for reference only. Use the Compatibility Checker to obtain specific information. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 45 The preceding information is for reference only. Use the Compatibility Checker to obtain specific information. NOTE The preceding information is for reference only. Use the Compatibility Checker to obtain specific information. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 46 ● Supports UEFI. ● Supports iBMC. ● Supports NC-SI. ● Supports integration with third-party management systems. Security feature ● Power-on password ● Administrator password ● TCM (only in China)/TPM ● Secure boot Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 47: Environment Specifications

    1°C (1.8°F) for every increase of 125 m (410.1 ft). ● HDDs cannot be used at an altitude of over 3050 m (10006.44 ft). Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 48 6 months in unpacked/packed and powered-off state ● The maximum preservation duration is determined according to the preservation specifications provided by drive vendors. For details, see the manuals provided by drive vendors. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 49: Physical Specifications

    – Ball bearing rail kit: applies to cabinets with a distance of 610 mm to 914 mm (24.02 in. to 35.98 in.) between the front and rear mounting bars. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 50 ● Packaging materials: 9 kg (19.84 lb) Energy consumption The power consumption parameters vary with server configurations, including the configurations complying with energy-related products (ErP) requirements. Use the Power Calculator to obtain specific information. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 51: Software And Hardware Compatibility

    ● If the customer has requirements on hardware performance consistency, specify the specific configuration requirements (for example, specific drive models, RAID controller cards, or firmware versions) in the pre-sales phase. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 52: Safety Instructions

    Discontinue any dangerous operations and take protective measures. Report anything that could cause personal injury or device damage to a project supervisor. ● Do not move devices or install racks and power cables in hazardous weather conditions. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 53 Tighten the strap buckle and ensure that the ESD wrist strap is in contact with your skin. Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 54 Transportation precautions include but are not limited to: ● The logistics company engaged to transport the device must be reliable and comply with international standards for transporting electronics. Ensure that the Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 55: Maintenance And Warranty

    For more information about safety instructions, see Server Safety Information. 8.2 Maintenance and Warranty For details about the maintenance policy, visit Customer Support Service. For details about the warranty policy, visit Warranty. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 56: System Management

    Integrates with any standard management system through the following interfaces: ● IPMI ● CLI ● HTTPS ● SNMP ● Redfish Fault Detection Detects and accurately locates faults in a field replaceable unit (FRU). Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 57 IPv6 Supports IPv6 to help build an all-IPv6 environment. Network Controller Supports NC-SI, allowing access to the iBMC Sideband Interface (NC-SI) through the service network port. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 58: Certifications

    Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe RoHS 2011/65/EU&(EU)2015/863, EN 50581: 2012 China GB 17625.1-2022 GB 4943.1-2022 GB/T 9254.1-2021(Class A) Japan VCCI VCCI 32-1 Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 59: Waste Product Recycling

    FusionServer CX5200 V5 Server Technical White Paper 11 Waste Product Recycling Waste Product Recycling If product users need product recycling service provided by xFusion after products are scrapped, contact technical support for services. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 60: A Appendix

    The label information and location are for reference only. For details, see the actual product. A.1.1 On the Front Top Figure A-1 Chassis head label Nameplate Certificate Quick access tag NOTE For details, see A.2 Product Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 61: Nameplate

    A.1.1.1 Nameplate Figure A-2 Nameplate example Table A-1 Nameplate description Description Server model For details, see the A.4 Nameplate Model. Device name Power supply requirements Vendor information Certification marks Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 62: Certificate

    The value for this digit is P, which is fixed. The value for this digit is Z, which is fixed. ● Y: indicates a server. ● B: indicates a semi-finished server. ● N: indicates a spare part. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 63: Quick Access Tag

    ● Letters P to Q indicate 23:00 to 24:00. Indicates the serial number (two digits). Indicates the manufacturing serial number (five digits). A.1.1.3 Quick Access Tag Figure A-5 Sample quick access tag Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 64: Chassis Tail Label

    The serial number (SN) on the slide-out label plate uniquely identifies a device. The SN is required when you contact technical support. Figure A-7 Figure A-8 show the SN formats. ● SN example 1 Figure A-7 SN example 1 Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 65 – Letters A to C indicate October to December, respectively. Serial number (six digits). RoHS compliance (one character). Y indicates RoHS compliant. Internal model (product name) of the board. The model format varies according to the actual situation. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 66: Operating Temperature Limitations

    Table A-7 Supported RAS features Module Feature Description Corrected Machine Check Corrects error-triggered interrupts. Interrupt (CMCI) Memory Failed DIMM Isolation Identifies faulty DIMMs to facilitate isolation and replacement of the faulty DIMMs. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 67 Socket disable for FRB Isolates a faulty socket during the BIOS (Fault Resilient Boot) startup process to improve system reliability. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 68: Sensor List

    Component in position U4214 on the mainboard CPUN Core Rem CPU core temperature CPU. N indicates the CPU number. The value CPUN DTS CPU DTS value is 1 or 2. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 69 PSU. N indicates the number of the PSU. The value is 1 or 2. CPUN Status CPU status detection CPU. N indicates the CPU number. The value is 1 or 2. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 70 N/A. N indicates the component number. PwrOk Sig. Drop Voltage sag status ACPI State ACPI status SysFWProgress Software processes and system startup errors SysRestart System restart causes Boot Error Boot error Watchdog2 Watchdog Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 71 Faulty BBUor low voltage of the standard PCIe card BMC Time Hopping Time hopping NTP Sync Failed NTP synchronization failure and recovery events Host Loss System monitoring software (iBMA) link loss detection Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 72 Mainboard standby 3.3 V voltage Standby 1.8V Mainboard standby 1.8 V voltage Standby 1.5V Mainboard standby 1.5 V voltage CPUN VCore 1.8 V CPU voltage CPUN DDR VDDQ CPU memory voltage Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 73 Sensor Description Location CPU memory voltage CPUN DDR VDDQ2 CPUN VSA CPU VSA voltage CPUN VCCIO CPU VCCIO voltage PCH VPVNN PCH PVNN voltage PCH PRIM 1V05 PCH1.05 V voltage Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 74: B Glossary

    Ethernet standards. It is compatible with 10M and 100M Ethernet and complies with IEEE 802.3z standards. hot swap Replacing or adding components without stopping or shutting down the system. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 75: K-O

    A special computer that provides services for clients over a network. system event log Event records stored in the system used for subsequent (SEL) fault diagnosis and system recovery. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 76: U-Z

    A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet or chassis. 1 U = 44.45 mm UltraPath A point-to-point processor interconnect developed by Interconnect (UPI) Intel. Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 77: C Acronyms And Abbreviations

    Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System calendar day Conformite Europeenne Common Information Model command-line interface Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 78: F-J

    Execute Disable Bit European Efficiency enterprise resource planning European Telecommunication Standards C.2 F-J FB-DIMM Fully Buffered DIMM Fiber Channel Federal Communications Commission FCoE Fibre Channel over Ethernet File Transfer Protocol Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 79 Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input/output operations per second Internet Protocol intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 80: K-O

    NC-SI Network Controller Sideband Interface C.4 P-T PCIe Peripheral Component Interconnect Express power distribution unit physical layer PMBUS power management bus power OK pulse-width modulation Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 81 SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol serial over LAN SONCAP Standards Organization of Nigeria-Conformity Assessment Program solid-state drive Streaming SIMD Extensions Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 82: U-Z

    Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc. Universal Serial Bus VCCI Voluntary Control Council for Interference by Information Technology Equipment Video Graphics Array VLAN virtual local area network voltage regulator-down Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 83 FusionServer CX5200 V5 Server Technical White Paper C Acronyms and Abbreviations WEEE waste electrical and electronic equipment WSMAN Web Service Management Issue 03 (2023-12-13) Copyright © xFusion Digital Technologies Co., Ltd.