Section 5 • Troubleshooting Flow Charts
TROUBLESHOOTING FLOW CHARTS
About This Section
When a malfunction is discovered, the flow charts
in this section will help a service professional
pinpoint the cause of the problem. To use this
section, basic hand tools and certain pieces of test
equipment are required—voltmeter, ohmmeter,
pressure gauges.
The location of terminals mentioned in this section
can be found on the appropriate electrical or
hydraulic schematics provided in Section 6,
Schematics.
Since various degrees of a particular function
loss may occur, selecting the appropriate flow
chart may be troublesome. When a function will
not operate with the same speed or power as a
machine in good working condition, refer to the
flow chart which most closely describes the
problem.
5 - 2
Genie Z-20/8N & Genie Z-20/8 & Genie Z-25/8
General Repair Process
Malfunction
Identify
discovered
symptoms
problem
still exists
Return to
Inspect
service
and test
problem
solved
First Edition • Third Printing
Troubleshoot
Perform
repair
Part No. 41314