Checking for
Installed Plug-Ins
SCPI Command Basics 5-40
The MOD:LIST? command may be used to query the 1256 for the
types and slot numbers of the cards present in the system.
[ROUTe]
:MODule
:LIST? [module address]
As an example, if a 1256 contains a 1260-136A, 1260-167B, and a
1260-138 in slots 4, 7, and 8 respectively, supposing that the
following command was executed:
MOD:LIST?
the reply would be:
4 : 1260-136A HIGH CURRENT 1X42 (2X21)
MUX,7 : 1260-167B DUAL 1x6 RF SWITCHING
MODULE,8 : 1260-138 64-CHANNEL DPST 2A MUX
Individual slots can also be queried:
MOD:LIST? (@7)
Where the reply would be:
7 : 1260-167B DUAL 1x6 RF SWITCHING MODULE
This command is NOT defined in the SCPI standard. This
command follows the syntax rules of SCPI to implement this
functionality.