Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
RACAL INSTRUMENTS 1260-37 SWITCH MODULE PUBLICATION NO. 980673-024 EADS North America Defense Test and Services, Inc. 4 Goodyear, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 info@eads-nadefense.com sales@eads-nadefense.com helpdesk@eads-nadefense.com http://www.eads-nadefense.com PUBLICATION DATE: December 11, 2000 Copyright 1994 by EADS North America Defense Test and Services, Inc. Printed in the United States of America. All rights reserved.
Page 3
THANK YOU FOR PURCHASING THIS EADS NORTH AMERICA DEFENSE TEST AND SERVICES PRODUCT For this product, or any other EADS North America Defense Test and Services, Inc. product that incorporates software drivers, you may access our web site to verify and/or download the latest driver versions. The web address for driver downloads is: http://www.eads-nadefense.com/downloads If you have any questions about software driver downloads or our privacy policy, please contact us at...
Page 4
RETURN of PRODUCT Authorization is required from EADS North America Defense Test and Services, Inc. before you send us your product for service or calibration. Call or contact the Customer Support Department at 1-800-722-3262 or 1- 949-859-8999 or via fax at 1-949-859-7139. We can be reached at: helpdesk@eads-nadefense.com. PROPRIETARY NOTICE This document and the technical data herein disclosed, are proprietary to EADS North America Defense Test and Services, Inc., and shall not, without express written permission of EADS North America Defense Test...
Page 5
FOR YOUR SAFETY Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the WARNINGS and CAUTION notices. This equipment contains voltage hazardous to human life and safety, and is capable of inflicting personal injury. If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure the common connector is connected to the neutral (earth pole) of the power supply.
Page 7
This page was left intentionally blank. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 8
1260-37 User Manual NOTE FOR SYSTEMS WITH 1260-OPT 01T The “Module-Specific Syntax” section of this manual shows the command syntax for the 1260-01S Smart Card. If you are using the newer 1260-01T Smart Card, the commands will NOT work as shown.
Page 9
1260-37 User Manual Control Information for the 1260-37A The following information describes the control-register-to-relay-channel mapping for a 1260-37A Relay Module. This information may be used to control a 1260-37A when using a 1260-01T in the register-based mode of operation. The table below shows the mapping between logical channels used to operate the relay module in message-based mode and the bits within the Control Registers which may be used to operate the channel in register-based mode.
Page 10
1260-37 User Manual Channel Control Register Control Bit Addendum Page 6/98 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 11
1260-37 User Manual Control Information for the 1260-37B The following information describes the control-register-to-relay-channel mapping for a 1260-37B Relay Module. This information may be used to control a 1260-37B when using a 1260-01T in the register-based mode of operation. Each relay on this module is controlled by setting or clearing a single bit. Control Registers on the module operate 8 channels simultaneously.
Page 12
1260-37 User Manual Channel Control Register Control Bit Addendum Page 6/98 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 13
1260-37 User Manual This page was left intentionally blank. 6 Addendum Page 6/98 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 16
1260-37 User Manual List of Figures Figure 1-1, 1260-37 Switching Card ....................1-1 Figure 3-1, 1260-37 Multiplexer/Scanner Circuit Block Diagram ............ 3-7 Figure 3-2, 1260-37 40-Channel SPDT Circuit Block Diagram............3-8 Figure 3-3, 1260-37 Pin Connections ..................... 3-9 List of Tables Table 2-1, 1260-37 Multiplexer/Scanner Circuit Jumper Installation ..........
Page 17
1260-37 User Manual This page was left intentionally blank. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
1260-37 User Manual Chapter 1 MODULE SPECIFICATION The 1260-37 switch module consists of two switch circuits; a 1 x 1260-37 Module 48 Signal Multiplexer/Scanner and a 40-Channel SPDT Switch. Specification The Signal Multiplexer circuit switches two lines per channel, and...
1260-37 User Manual 1 x 48 Signal Multiplexer/Scanner Specifications Switch Configurations Four-wire mode (any configuration) Two-wire mode (any configuration) Maximum Switchable Voltage 250 VDC, 250 VAC RMS (Terminal-Terminal or Terminal-Chassis) Maximum Switchable Current 1A, DC or AC RMS (Per Channel) Maximum Switchable Power 30 WDC, 62.5 VA AC...
Page 20
1260-37 User Manual 40 Channel SPDT Switch Maximum Switchable Voltage 250 VDC, 250 VAC RMS (Terminal-Terminal or Terminal Chassis) Maximum Switchable Current 1 A,DC or AC RMS (Per Channel) Maximum Switchable Power 30 WDC, 62.5 VA AC (Per Channel) <0.5 Ω...
1260-37 User Manual *A crimp connector kit is also available for this module (P/N 404975-003). A strain relief option can be ordered separately for this crimp connector kit. Ordering Information Model Number Description Part Number 1260-37 1 x 48 Signal Multiplexer/...
1260-37 User Manual Chapter 2 INSTALLATION INSTRUCTIONS 1. Remove the 1260-37 module and inspect it for damage. If any Unpacking and damage is apparent, inform the carrier immediately. Retain Inspection shipping carton and packing material for the carrier’s inspection. 2. Verify that the pieces in the package you received contain the correct 1260-37 module option and the 1260-37 Users Manual.
Each configuration responds to different sets of values for <channel number>. The set of values the 1260-37 responds to is controlled by switch 5 on DIP switch 51 on the main PCB. The switch settings that correspond to the two configurations are as follows:...
1260-37 User Manual Table 2-1, 1260-37 Multiplexer/Scanner Circuit Jumper Installation An X indicates a jumper is to be installed. An (X) indicates the jumper is optional, depending on whether access to the analog bus is required. A blank indicates no jumper is to be installed.
Specific Syntax CLOSE commands. It will also appear in data output by the Master in response to the PDATAOUT and PSETUP commands. The Module Specific Syntax for the 1260-37 module is as follows: Syntax <module address> .<channel>[ ;<module address> <channel>] where <module address>...
VXI Controller. The syntax used is: PSETUP <module address>[ ;<module address>] [;<module address>] where <module address> is the switch card address. The responses to the PSETUP command for the 1260-37 Scanner/Multiplexer / SPDT is as follows: 1260-37: Two-wire <module address>.
Again, the last line is denoted by the "END" string of characters. The 1260-37 is delivered with all jumpers installed (refer to Table Operation In 2-1). In this configuration, the module is a 1 x 48 two-wire Single-Wire Mode multiplexer (refer to Figure 3-1).
I multiplexer, and the 48 HI and 48 LO connections make up the 96 channels. By closing the appropriate channel (0-47) and opening or closing channel 48, a 96 x I multiplexer is achieved. Table 3-1, 1260-37 Multiplexer/Scanner Circuit Channel Closure Channel interconnect for 1, 2 and 4-wire modes. 1-wire mode: <channel>...
1260-37 User Manual Chapter 4 OPTIONAL HARNESS ASSEMBLIES The following harness assemblies are used to connect 1260-37 to Freedom Series Test Receiver Interfaces. Each harness documentation consists of an assembly drawing, parts list, system wire list and wire list. 407437 Virginia Panel, Inc.
For worldwide support and the office closest to your facility, refer to the website for the most complete information http://www.eads- nadefense.com. Use the original packing material when returning the 1260-37 to Warranty EADS North America Defense Test and Services, Inc. for calibration or servicing.
Page 59
1260-37 User Manual REPAIR AND CALIBRATION REQUEST FORM To allow us to better understand your repair requests, we suggest you use the following outline when calling and include a copy with your instrument to be sent to the EADS North America Defense Test and Service, Inc.
Page 60
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...