Racal Instruments 1260-100 Manual

Adapt-a-switch carrier module

Advertisement

Quick Links

ADAPT-a-SWITCH
CARRIER MODULE
MODEL 1260-100/101
Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139
5730 Northwest Parkway Suite 700, San Antonio, TX 78249
Tel: +33 (0)1 39 23 22 22; Fax: +33 (0)1 39 23 22 25
29-31 Cobham Road, Wimborne, Dorset BH21 7PF, United Kingdom
Tel: +44 (0) 1202 872800; Fax: +44 (0) 1202 870810
Tel: +39 (0)2 6123 901; Fax: +39 (0)2 6129 3606
Racal Instruments Group Limited, Technologie Park, D-51429 Bergisch Gladbach, Germany
Copyright 1998 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved.
This book or parts thereof may not be reproduced in any form without written permission of the publisher.
PUBLICATION NO. 980824-100
RACAL INSTRUMENTS
United States
(Corporate Headquarters and Service Center)
4 Goodyear Street, Irvine, CA 92618
Tel: (210) 699-6799; Fax: (210) 699-8857
Europe
(European Headquarters and Service Center)
18 Avenue Dutartre, 78150 LeChesnay, France
Via Milazzo 25, 20092 Cinisello B, Milan, Italy
Tel: +49 2204 844205; Fax: +49 2204 844219
info@racalinstruments.com
sales@racalinstruments.com
helpdesk@racalinstruments.com
http://www.racalinstruments.com
info@racalinstruments.de
www.racalinstruments.de
PUBLICATION DATE: July 26, 2004

Advertisement

Table of Contents
loading

Summary of Contents for Racal Instruments 1260-100

  • Page 1 PUBLICATION DATE: July 26, 2004 Copyright 1998 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved. This book or parts thereof may not be reproduced in any form without written permission of the publisher.
  • Page 2 THANK YOU FOR PURCHASING THIS RACAL INSTRUMENTS PRODUCT. For this product, or any other Racal Instruments product that incorporates software drivers, you may access our web site to verify and/or download the latest driver versions. The web address for driver downloads is: http://www.racalinstruments.com/downloads...
  • Page 3 Authorization is required from Racal Instruments before you send us your product for service or calibration. Call your nearest Racal Instruments support facility. A list is located on the last page of this manual. If you are unsure where to call, contact Racal Instruments, Inc. Customer Support Department in Irvine, California, USA at 1-800-722-3262 or 1-949-859-8999 or via fax at 1-949-859-7139.
  • Page 4 FOR YOUR SAFETY Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the WARNINGS and CAUTION notices. This equipment contains voltage hazardous to human life and safety, and is capable of inflicting personal injury. If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure the common connector is connected to the neutral (earth pole) of the power supply.
  • Page 6 This page was left intentionally blank.
  • Page 8 This page was left intentionally blank.
  • Page 9: Table Of Contents

    Module Address Switch......................2-7 1260-100 Module Address ....................2-7 1260-101 Module Address ....................2-9 Inserting and Removing Plug-Ins ....................2-9 Installing the 1260-100/101 into a VXIbus Chassis..............2-9 Making Connections to Plug-Ins (Pin-Outs) ................2-10 Power-On Self-Test........................2-10 Closing and Opening Relays....................2-10 Chapter 3 ..........................
  • Page 10 1260-100/101 Adapt-a-Switch Carrier Module User Manual Description..........................3-1 Interface..........................3-2 Normal State of External Switch ..................... 3-2 Scope of Reset Event ......................3-2 Sequence of Events ....................... 3-2 Chapter 4 ..........................4-1 MAINTENANCE..........................4-1 Performance Verification Procedure ..................4-1 Purpose ..........................4-1 Equipment Required .......................
  • Page 11 1260-100/101 Adapt-a-Switch Carrier Module User Manual List Of Figures Figure 1-1, The 1260-100 ......................1-1 Figure 1-2, 1260-100 Adapt-a-Switch Carrier ................1-2 Figure 1-3: Ease-of-Use Features ....................1-4 Figure 2-1, Installing the Option-01T .....................2-5 Figure 2-2, Configuration Switches....................2-6...
  • Page 12 1260-100/101 Adapt-a-Switch Carrier Module User Manual This page was left intentionally blank.
  • Page 13: Chapter 1

    1260-100/101 Adapt-a-Switch Carrier Module User Manual Chapter 1 OVERVIEW The following items are shipped with each 1260-100/101 Adapt-a- ITEMS SHIPPED Switch Carrier: WITH 1260-100/101 ITEM RACAL PART NUMBER QUANTITY Lockout key, type A 456663-001 Lockout key, type C 456663-002 Blanking plate...
  • Page 14: Figure 1-2, 1260-100 Adapt-A-Switch Carrier

    1260-100/101 Adapt-a-Switch Carrier Module User Manual DESCRIPTION that may contain up to six Adapt-a-Switch plug-ins. You may leave some slots unoccupied for future expansion. The 1260-101 Adapt-a-Switch Carrier is a single-slot VXIbus module that contains two Adapt-a-Switch plug-ins. Figure 1-2 shows the 1260-100 with plug-ins.
  • Page 15: Features

    1260-100 model is shown in Figure 1-3): • Plug-ins are easy to insert and extract from the front panel of the 1260-100/101, even while it is installed in a chassis. • For only the1260-100, module addresses, used to uniquely identify each plug-in, are set by a single DIP switch that is easily accessible from the side panel of the 1260-100.
  • Page 16: Dynamically-Configured Analog Bus

    Shield Between PLUG-INS For Maximum Signal Isolation Figure 1-3: Ease-of-Use Features The 1260-100 /101 Adapt-a-Switch Carrier offers an analog bus to Dynamically- interconnect two or more plug-ins. This allows the creation of Configured large multiplexers and matrices.
  • Page 17: Chapter 2

    ESD sensitive devices, open the instrument at an ESD safe work station. 1. Use the original packing material when returning the RESHIPMENT switching module to Racal Instruments for servicing. The INSTRUCTIONS original shipping carton and the instrument’s plastic foam will provide the necessary support for safe reshipment.
  • Page 18: Option-01T

    1260-100/101 Adapt-a-Switch Carrier Module User Manual The 1260-100/101 may be ordered with or without the Option-01T. OPTION-01T If the Option-01T is included, it controls all plug-ins inside the 1260-100/101. It may also control plug-ins in an adjacent 1260-100/101 module, or several 1260-Series modules in consecutive slots.
  • Page 19 1260-Series switch modules and Adapt-a-Switch plug- ins. The maximum number of items in each group is twelve. Each 1260-100 carrier counts as six plug-ins and each 1260-101 carrier counts as two plug-ins, regardless of the quantity of plug-ins actually installed.
  • Page 20 7. Re-install the Bridge module. 8. Re-install the access panel and secure with screws. 9. The user may want to mark the 1260-100 to indicate that the 01T is installed. Racal Instruments  1998 Getting Started 2-4...
  • Page 21: Figure 2-1, Installing The Option-01T

    Bridge Board Option-01T Mezzanine Board Figure 2-1, Installing the Option-01T in the 1260-100 (For the 1260-101 single-slot carrier, see text below) For the 1260-101 follow the instructions below: 1. Remove the eight screws from the access panel. Remove the access panel.
  • Page 22: Setting Configuration Switches

    Immediately to the Right Auto-Configuration. Figure 2-2, Configuration Switches Set these switches as follows. If you are using a 1260-100/101 Carrier by itself, with no switch Local Bus Daisy- modules or carriers to its right, set all twelve local bus daisy-chain Chain Switches switches to the OPEN position.
  • Page 23: Module Address Switch

    1260-100 Module Address The module address DIP switch (see figure 2-2) sets the logical addresses for all plug-ins in the 1260-100 Carrier. The switch has two settings: • 1-6 (closed) When the switch is set to this position, the...
  • Page 24 1260-100/101 Adapt-a-Switch Carrier Module User Manual The Front View – One 1260-100 • 7-12 (open) When the switch is set to this position, the module addresses of the plug-ins are from 7 through 12, in the following pattern: The Front View – Two 1260-100s Racal Instruments ...
  • Page 25: 1260-101 Module Address

    INSERTING AND CAUTION REMOVING If the 1260-100/101 Carrier is in a VXIbus chassis, make PLUG-INS sure the chassis power is off before inserting or removing plug-ins. Use proper anti-static handling procedures when plug- ins are outside the carrier.
  • Page 26: Making Connections To Plug-Ins (Pin-Outs)

    1260-100/101 Adapt-a-Switch Carrier Module User Manual To remove the 1260-100/101 Carrier from the VXIbus chassis, loosen the upper and lower retaining screws. Simultaneously push the upper injector handle upward and pull the lower handle downward until the carrier is disengaged from the chassis backplane.
  • Page 27: Chapter 3

    1260-100/101 Adapt-a-Switch Carrier Module User Manual Chapter 3 USING THE 1260-100/101 CHECKING THE To verify that the plug-ins are operational, send the MOD:LIST? command to the Option-01T. Then read back the response of the RESPONSE OF Option-01T. The Option-01T responds with a message specifying PLUG-INS which plug-ins and 1260-Series modules are under its control.
  • Page 28: Interface

    1260-100/101 Adapt-a-Switch Carrier Module User Manual Select Adapt-a-Switch plug-ins and 1260-Series modules have a Interface pair of front-panel-mounted connector pins. You may connect these to an external device such as a mechanical switch. When the switch is opened, all relays on the plug-in or module are immediately opened.
  • Page 29 1260-100/101 Adapt-a-Switch Carrier Module User Manual 3. An interrupt is generated to notify the Option-01T that a reset event has occurred. This informs the Option-01T that the relays have opened, so that it remains up-to-date on the relay status. 4. The relays remain open and do not respond to any commands from the Option-01T.
  • Page 30 1260-100/101 Adapt-a-Switch Carrier Module User Manual This page was left intentionally blank. Racal Instruments  1998 Using the 1260-100/101 3-4...
  • Page 31: Chapter 4

    1260-100/101 Adapt-a-Switch Carrier Module User Manual Chapter 4 MAINTENANCE PERFORMANCE VERIFICATION PROCEDURE The following procedure verifies the basic functions of the Purpose 1260-100/101 Adapt-a-Switch Carrier. Test coverage includes: • Option-01T power-on self-test • Option-01T basic operation in message based mode •...
  • Page 32 Remove all other modules from the chassis except the slot 0 controller. 5. Insert one or more plug-ins into the 1260-100/101 Carrier. 6. Turn the chassis power on. Verify that the Fail LED on the carrier illuminates, then extinguishes within five seconds.
  • Page 33 5 through 18 with the plug-ins in different slots until all carrier slots have been tested. 26. For the 1260-100 set the module address switch on the carrier to the 7-12 position. Repeat steps 5 through 20. When calculating the address offset in step 12, remember that the module addresses now range from 7 through 12.
  • Page 34 1260-100/101 Adapt-a-Switch Carrier Module User Manual This page was left intentionally blank. Racal Instruments  1998 Maintenance 4-4...
  • Page 35: Chapter 5

    Support Offices section on the following page. WARRANTY Use the original packing material when returning the 1260- 100/101 to Racal Instruments for calibration or servicing. The original shipping container and associated packaging material will provide the necessary protection for safe reshipment.
  • Page 36: Support Offices

    1260-100/101 Adapt-a-Switch Carrier Module User Manual SUPPORT RACAL INSTRUMENTS OFFICES United States (Corporate Headquarters and Service Center) 4 Goodyear Street, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 5730 Northwest Parkway Suite 700, San Antonio, TX 78249 Tel: (210) 699-6799;...
  • Page 37: Repair And Calibration Request Form

    1260-100/101 Adapt-a-Switch Carrier Module User Manual REPAIR AND CALIBRATION REQUEST FORM To allow us to better understand your repair requests, we suggest you use the following outline when calling and include a copy with your instrument to be sent to the Racal Instruments Repair Facility.
  • Page 38: Specifications

    1260-100/101 Adapt-a-Switch Carrier Module User Manual Appendix A 1260-100 SPECIFICATIONS 1260 Series Compatibility Option-01T simultaneously controls General combination of Adapt-a-Switch plug-ins and 1260-Series switch modules Annunciators FAIL: Self-test failure indicator LED Host Interface VXIbus backplane Control Type Message-based. Register based: VXIbus A24 address space.
  • Page 39 1260-100/101 Adapt-a-Switch Carrier Module User Manual Power Consumption +5V: 1.0A Power and Cooling (without plug-ins) +12V: 0A +24V: 0A Power Available +5V: 2.5A (per plug-in) +12V: 1.0A +24V: 1.0A Cooling (worst-case Airflow: 3.0 liters/sec plug-in configuration) Backpressure: 0.7 mm H...
  • Page 40 1260-100/101 Adapt-a-Switch Carrier Module User Manual 1260-101 SPECIFICATIONS 1260 Series Compatibility Option-01T simultaneously controls General combination of Adapt-a-Switch plug-ins and 1260-Series switch modules Annunciators FAIL: Self-test failure indicator LED Host Interface VXIbus backplane Control Type Message-based. Register based: VXIbus A24 address space.
  • Page 41 1260-100/101 Adapt-a-Switch Carrier Module User Manual Power Available +5V: 4.5A (per plug-in) +12V: 0.75A +24V: 0.75A Cooling (worst-case Airflow: 1.5 liters/sec plug-in configuration) Backpressure: 0.7 mm H Temperature Operating: 0°C to +55°C Environmental Non-operating: -40°C to +70°C Relative Humidity 95% RH non-condensing...
  • Page 42: Theory Of Operation

    One schematic (P/N 435138,-001) covers both the Mezzanine and Bridge. General The Mezzanine PCB serves two functions. It connects +5V, +12V, and +24V power from the VXIbus backplane to the 1260-100 backplane. It also connects the VXIbus backplane signals to the Option-01T if it is installed. Power Filtering The power is filtered before reaching either the backplane or Option-01T.
  • Page 43 1260-100 Carrier has access to the local bus signals from the Option-01T. If the module to the right of the 1260-100 Carrier is not meant to be controlled by the Option-01T, then all segments of DIP switches S1 and S2 should be open.
  • Page 44 The 13 address bits are clocked into a shift register comprised of U5 and U6. The parallel outputs of this shift register are connected directly to all six plug-ins via the 1260-100 backplane. After sending the address, The Option-01T drives HLBUS_A/D low, indicating that the next data sent will be data.
  • Page 45 0. Power Distribution The Bridge PCB connects +5V, +12V, and +24V power from the VXIbus backplane to the 1260-100 backplane to add to the current provided by the Mezzanine. The bridge also filters power in the same manner as the Mezzanine.
  • Page 46 1260-100/101 Adapt-a-Switch Carrier Module User Manual 1260-101 THEORY OF OPERATION General Power Filtering The power is filtered before reaching either the backplane or Option-01T. The fuses, F1 through F3, are of the surface-mount type. The fuses used are as follows.
  • Page 47 1260-100/101 Adapt-a-Switch Carrier Module User Manual Signals All communications signals are connected in parallel to the two plug-ins, except LBOARDSEL1 and LBOARDSEL2. These two signals route to their respective plug-in slots, and identify which plug-in is currently addressed. The Mezzanine also provides an analog bus. This bus consists of four pairs of PCB traces that daisy-chain from one plug-in to the next, connecting to the two slots in parallel.
  • Page 48 1260-100/101 Adapt-a-Switch Carrier Module User Manual LBUSC10S also connects to all other devices controlled by the same Option-01T. When any device in this group asserts a global reset, all devices in the group respond by resetting their drivers. Interrupt The signal LBUSC11S is an open-collector line to the Option-01T. It has two purposes. When a plug-in asserts an emergency reset condition, it drives the LBUSC11S signal low.
  • Page 49 1260-100/101 Adapt-a-Switch Carrier Module User Manual PLD Programming Connector J5 is a 10-pin header that is connected to the PLD (U1). It uses the JTAG interface to allow in- system programming of the PLD during upgrades or troubleshooting.
  • Page 50: Troubleshooting

    Appendix C TROUBLESHOOTING If you have difficulty in using the 1260-100/101 Adapt-a-Switch Carrier or its plug-ins, refer to the following troubleshooting table. If you are still unable to resolve the problem, contact one of the Racal Customer Support offices listed in Chapter 5: Support Offices.
  • Page 51 If the Option-01T responds with a message in this form, then proceed to step 3. Otherwise, go to step 8. 3. Execute the Racal Instruments 1260-Series soft front panel program. It should display a list of all plug-ins and 1260-Series modules that are connected to the Option-01T. If it does not display a list, then go to step 8.
  • Page 52 If this does not correct the problem, then proceed to step 11. Try to isolate the problem to a single 1260-100/101 Carrier or 1260-Series module by removing others from the chassis. Remember always to install the Option-01T in the module that is left-...
  • Page 53 1260-100/101 Adapt-a-Switch Carrier Module User Manual This page was left intentionally blank.

This manual is also suitable for:

1260-101

Table of Contents