Care, cleaning and full service
„ Take the insulation off the heat exchanger cover – Fig. 52.
„ Connect the device power plug – Fig. 53.
„ Unscrew the screw connection on the cover and lift the cover out – Fig. 54, Fig. 55.
Fig. 52
Remove the insulation
Fig. 54
Unscrew the screw connection
„ Clean the induced draught fan wheel with a brush – Fig. 56.
„ Clean the top of the heat exchangers with a spatula and brush – Fig. 57.
„ Vacuum out the ash from the heat exchangers – Fig. 58.
Fig. 56
Clean and vacuum the induced draught fan wheel
Fig. 58
Vacuum out the ash
Assembly:
„ By working through these steps in reverse order.
Fig. 53
Disconnect the device power plug
Fig. 55
Li off the cover
Fig. 57
Clean the heat exchangers