Care, cleaning and full service
Fig. 31
Pull out the handle
„ Push the ash box slightly to the left and pull it out – Fig. 33, Fig. 34.
„ Release the side bracket fasteners, remove the cover and empty the ash box – Fig. 35, Fig. 36.
Fig. 33
Push the ash box slightly to the le
Fig. 35
Open the side bracket fasteners, remove the cover and empty
the ash box
Note.
The size of the box is related to the max. ash content of the pellets. If the ash box is not full when a cleaning
request is issued, then the ash content will be lower.
Assembly:
„ Reinstall the ash box by working through these steps in reverse order.
„ Important: Slide the ash box handle all the way back in.
CAUTION Material losses
„ When reinstalling the ash box and cover, check they are in the correct position and are sealed – danger of
induced air.
DANGER Attention. Risk of fire.
The boiler must not be operated without the ash box.
Fig. 32
Open the bracket fastener
Fig. 34
Take out the ash box
Fig. 36
Empty the ash box
34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Biowin 152Biowin 212Biowin 262Biowin 332

Table of Contents