Windhager BIOWIN 2 TOUCH Operating Manual page 32

Pellet boiler
Hide thumbs Also See for BIOWIN 2 TOUCH:
Table of Contents

Advertisement

Care, cleaning and full service
„ Remove the ash pan and place it in front of the boiler – Fig. 27.
„ Use the Allen key to turn down the handle on the cover (heat exchanger) in a clockwise direction and remove the
cover – Fig. 28.
Fig. 27
Remove the ash pan and place it in front of the boiler
„ Use the scraper to remove ash from underneath the heat exchanger into the ash pan – Fig. 29.
Fig. 29
Remove ash from below heat exchanger into ash pan
Assembly:
„ Clean away all ash, the heat exchanger cover should fit/seal tightly.
„ Position the cover (heat exchanger) and turn the handle as far as it will go in a clockwise direction – Fig. 30.
„ Push the ash pan into place.
„ Close the combustion chamber door and the cladding door and switch the BioWIN 2 Touch back on with the ON/OFF
button.
„ Confirm the cleaning request once "Cleaning" is complete – see section 14.1.
CAUTION Material losses
„ When reinstalling the ash pan and cover, ensure that they are in the correct position and are airtight.
Fig. 28
Turn handle and remove cover
Fig. 30
Rotate handle in an anti-clockwise direction
32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Biowin 152Biowin 212Biowin 262Biowin 332

Table of Contents