again turn on after the pump start delay time
has elapsed.
The Pumpfix
®
F can be programmed to be
either in ʻFinish Controlledʼ or ʻStart Controlle-
dʼ mode. To change to either ʻFinished Con-
trolledʼ or ʻStart Controlledʼ mode keep both
the ʻALARMʼ and ʻPUMPING / TEST PUMPʼ
buttons pressed for a few seconds until the
continuous audible alarm sounds. Release
the ʻALARM and ʻPUMPING / TEST PUMPʼ
buttons. Again press both the ʻALARMʼ and
ʻPUMPING / TEST PUMPʼ buttons for a few
seconds until the continous audible alarm
sounds and the ʻPOWERʼ and ʻALARMʼ
LEDs light. Again release the ʻALARMʻ and
ʻPUMPING / TEST PUMPʼ buttons. For the
third time press both the ʻALARMʼ and
ʻPUMPING / TEST PUMPʼ buttons depres-
sed for a few seconds. The control unit will
confirm that it is in ʻFinish Controlledʼ and
ʻStart Controlledʼ setting mode by a conti-
nuous audible signal along with the ʻPO-
WERʼ, ʻALARMʼ, and ʻPROBE SUBMER-
GEDʼ
LEDs
lighting.
6. Operation
releasing the ʻALARMʼ and ʻPUMPING /
TEST PUMPʼ buttons the current Control
setting can be determined by the blinking
LEDs (please see table below). To change
the Control setting press the ʻALARMʼ
button. The enterred Control setting can be
determined by looking at the blinking LEDs
and checking with the table below. When
the desired Control setting has been enter-
red, press the ʻPUMPING / TEST PUMPʼ
button to save the new setting. The new
Control setting will be confirmed by a two
toned audible signal. If within 20 seconds
the changes are not saved by pressing the
ʻPUMPING / TEST PUMPʼ button, the
Pumpfix
F will automatically save the
®
previous control setting (this will be confirmed
by a single tone audible signal). The
Pumpfix
®
F is delivered pre-programmed in
the ʻFinish Controlledʼ mode.
Mode
Finish
controlled
blinking LEDs
1
After
15

6.3 Alarms / Pump Test

ALARM - The "Alarm" button located on the
Pumpfix
®
F control unit can be used to can-
cel the audible alarm. The LED alarm light
will remain lit after the audible alarm has
been cancelled to notify the user of the cur-
rent problem / situation. If desired, the
"Alarm" button can be pressed again which
will re-activate the audible alarm.
PUMP TEST - The motor of the Pumpfix
can be manually started / tested by pressing
the "Pump" Test button. This can serve as a
quick and easy test to assure that the motor
is in working condition. Do not keep the
"Pump Test" button depressed for more
than a few seconds.
Start
controlled
2
®
F

Advertisement

Table of Contents
loading