Kessel Pumpfix-F 28100 S Installation And User Manual page 14

Backwater valve with sewage pump
Table of Contents

Advertisement

Setting the ʻPump start delayʼ times.
The Pumpfix
®
F can be programmed to
delay starting the pump after the optical sen-
sor has sensed wastewater. The advantage
of this is that the wastewater will have a
chance to build up in the pipe so that the
Pumpfix
®
F can pump out the entire volume
with one activation rather than turning on
and off several times. To change the ʻPump
start delayʼ times keep both the ʻALARMʼ
and ʻPUMPING / TEST PUMPʼ buttons pres-
sed for a few seconds until the continuous
audible alarm sounds. Release the ʻALARM
and ʻPUMPING / TEST PUMPʼ buttons.
Now again press both the ʻALARMʼ and
ʻPUMPING / TEST PUMPʼ buttons for a few
seconds until the continous audible alarm
sounds again and the ʻPOWERʼ and ʻALAR-
Mʼ LEDs light. After releasing the ʻALARMʼ
and
ʻPUMPING
/
buttons the current pump start delay time
setting can be determined by the blinking
LEDs (please see table below). To change
the pump start delay times press the ʻALAR-
Mʼ button. Each time the ʻALARMʼ
button is pressed, additional time will be
added to the pump start delay time. The
enterred times can be determined by looking
at the blinking LEDs and checking with the
table below. When the desired pump start
delay time has been enterred press the
ʻPUMPING / TEST PUMPʼ button to save the
new setting. The new ʻPump start delayʼ
times will be confirmed by a two toned
audible signal. If within 20 seconds the
changes are not saved by pressing the
ʻPUMPING / TEST PUMPʼ button, the
Pumpfix
previous ʻPump start delayʼ (this will be
confirmed by a single tone audible signal).
The Pumpfix
with a pump start delay time of 1 second.
TEST
PUMPʼ
Pump Start
Delay (sec.)
blinking LEDs
6. Operation
®
F will automatically save the
F is delivered pre-programmed
®
0,5 1,0 1,5 2,0 3,0 4,0 5,0
1
1+2
2
2+3
3
Setting to either ʻFinish Controlledʼ or ʻStart
Controlledʼ modes.
The Pumpfix
®
operate in either ʻFinish Controlledʼ or ʻStart
Controlledʼ modes. In the Finish Controlled
pump setting mode, the optical probe
senses the build-up of wastewater in the
drainage pipe and activates the Pumpfix
which will begin pumping after the program-
med delay start time has elapsed. In this
mode the pump will continue to run for the
programmed period of time after the
wastewater level has fallen below the optical
sensor level. In the Start Controlled pump
setting mode, the optical probe senses the
build-up of wastewater in the drainage pipe
and activates the Pumpfix
begin pumping after the programmed delay
start time has elapsed. In this mode the
pump will run for the programmed period of
time and then shut off. If there is still waste-
3+4
4
water above the sensor level the pump will
14
F can be programmed to
®
F which will
®
F