Name
When motor speed exceeds 30 rpm and the drive generates an alarm, if, within the specified brake close time
(P42), the actual motor speed becomes smaller than the P43 setpoint, brake is closed when the actual speed
reaches the speed P43 sets.
P44
Drive enable time after the
brake close
When motor speed is lower than 30 rpm, the drive remains enabled within the time period set by P44 after
brake close.
P46
JOG speed
This parameter specifies the motor speed in JOG mode.
P47
Ramp-up/-down time
constant
This parameter defines the time period when the motor ramps up from 0 rpm to 2,000 rpm or ramps down from
2, 000 rpm to 0 rpm.
P99
Reserved for Siemens internal use only
Note
The default values in brackets are the second default values.
3.3

Display data list

Data no.
Name
D10*
Torque setpoint
D11*
Actual value of the torque
D12*
Actual value of the phase
current
D20
Motor speed setpoint
D21
Actual motor speed
D30
Position revolution
setpoint
D31
Position angle setpoint
D32
Actual position
revolutions
D33
Actual position angle
D34
Position deviation angle
D50*
Digital input signal
D51*
Digital output signal
D80*
Firmware version
D81
Power Board rated
current
D82*
Parameter version
number
* The data type of D10, D11, D12, D80, D82 is all decimal format. The display value for D50 and D51 respectively varies as
the case may require.
Controlled Power Module (CPM60.1)
A5E03975175-002, 04/2014
Range
Default
20-2000
600
0-2000
200
0.0 –
4.0
10.0
Data format
Decimal
(See table below)
Integer
Bit (See table below)
(See table below)
Integer
(See table below)
Increment
Unit
10
ms
10
rpm
0.1
s
Unit
Nm
Nm
A
RPM
RPM
Motor revolutions
Increments (10000/r)
Motor revolutions
Increments (10000/r)
Increments (10000/r)
Bits in hex
Bits in hex
Effective
Power on
Immediately
Power on
Data group
Current
Speed
Position
I/O