WEG ADL300 User Manual page 25

Table of Contents

Advertisement

Menu
Par
Description
5.2.7
11054
Percent acc factor
Setting the acceleration coefficient multiplier.
If set to 100, the ramp uses the coefficients entered in the parameters.
If set to less than 100, the lift will tend to accelerate in a larger space.
If set to more than 100, the lift will tend to accelerate in a smaller space.
Menu
Par
Description
Percent dec factor
5.2.8
11056
Setting the deceleration coefficient multiplier.
If set to 100, the ramp uses the coefficients entered in the parameters.
If set to less than 100, the lift will tend to decelerate in a larger space.
If set to more than 100, the lift will tend to decelerate in a smaller space.
Menu
Par
Description
5.2.9
11258
Max End Jerk
This is the maximum configurable jerk value during deceleration. Parameter 11256 Comp Enable must be enabled.
ADL300 CiA® 417- Description of functions and parameter list