11.

INSTALLING THE APPLICATION

11.1 General

The preliminary operations for commissioning are describe in chapter 8 of the ADL300 QS manual.

11.2 Requirements

The DS 417 application for ADL300 requires firmware version 3.00 and later.
To install the application you need a PC, WEG GF Express software version 1.8 or later with Catalog, a connection cable
to the RS-232 drive, and the setup CD.
The CD for installing the application contains an automatic procedure that copies the required files to the specific folder
of the GF Express catalog. When installation is done, the setup procedure requests the following files / path:
Files containing DS417Application:
ADL300Asy_3_7_10_Fw_Lang_DS417_1_5_21_0__A2.fl2 (EPC for Synchronous Motors)
ADL300Syn_3_7_10_Fw_Lang_DS417_1_5_21_0__ A2.fl2 (EPC for Asynchronous Motors)

11.3 Preliminary operations

The drive can contain two applications ("Application 1" and "Application 2"). You can download the DS417 application to
"Application 2."
Files to be installed:
ADL300Asy_3_7_10_Fw_Lang_DS417_1_5_21_0__A2.fl2 (EPC for Synchronous Motors)
ADL300Syn_3_7_10_Fw_Lang_DS417_1_5_21_0__ A2.fl2 (EPC for Asynchronous Motors)
Refer to parameter menu 4.5 PAR 558 Application select to select which application to run.
When the application has been installed, do as follows:
1)
Send the "Drive reset" command via WEG_eXpress.
2)
Execute the "Load default drive values" command
3)
Execute the "Save parameter into target" command
4)
Execute the Drive reset command.
The application is now ready for use. The parameters are shown on menu 5 "LIFT".