Water Pressure Switch Replacement - Cornelius Viper E 2 Flavor Service Manual

Hide thumbs Also See for Viper E 2 Flavor:
Table of Contents

Advertisement

Step
Action
1
Disconnect power to the unit
2
Remove the appropriate side panel.
3
Turn off the syrup supply to the unit.
4
Drain the syrup from the system.
5
Disconnect the wires on the pressure switch.
6
Remove the switch, using two wrenches.
7
Replace the switch with a new unit.
8
Reverse the procedure to install the new switch.
9
Restore the syrup supply and check for leaks.
10
Check switch operation.
W
P
ATER
RESSURE
The water pressure switch, shown in Figure 53, is located in back of the water filter, when viewed from the rear of
the unit. Access to the switch is obtained by removing the left side panel of the unit, when viewed from the rear. To
replace the water pressure switch, perform the procedure in Table 57.
Water
Pressure
Switch
© 2008-2016, Cornelius Inc.
Syrup
Pressure
Switch
Figure 52. View of Syrup Pressure Switch and Valve
S
R
WITCH
EPLACEMENT
Figure 53. View of Water Pressure Switch
Table 56.