Installation; Counter Location; Filling The Ice Bath; Connecting Water Supply - Cornelius 2 Flavor Training Manual

Quest juice 2 and 4 flavor
Table of Contents

Advertisement

C
L
OUNTER
OCATION
The minimum airflow clearance is: 4" (10.16 cm) in back and 12" (30.48 cm) on top and open to the front.
IMPORTANT: Condenser air is drawn in from the bottom of the rear panel and discharged out the top of
the rear panel. Failure to maintain clearance space will reduce capacity of the unit and cause premature
compressor failure.
F
I
B
ILLING THE
CE
The fill tube is located behind the splash panel. Use the water supply line to fill the ice bath before con-
necting it to the unit.
Remove the 3/8" cap from the fill tube/sight glass to begin filling the ice bath. Replace the cap when fin-
ished filling the ice bath. Lock it in place with its holder.
IMPORTANT: Fill the water bath slowly until it runs out
the overflow. Failure to do so can cause back pres-
sure and improper water level. ALWAYS FILL WITH
THE UNIT UNPLUGGED.
Replace the cap TIGHTLY when finished filling the water bath. Lock it in place with its holder.
C
W
ONNECTING
ATER
The QST series Juice Dispenser is designed to dispense juice at a high flow rate. It is very important that
the incoming water line be dedicated for use by the dispenser only and does not have other machines
connected which could cause a water surge, (i.e., a dishwasher, coffee maker, etc.).
IMPORTANT: The water supply should be consistent with proper water quality standards (neutral pH of
7.0 to 8.0), and should not be connected to a water softener. It is the installers responsibility to ensure
that all water connections to the dispenser are sized, installed, and maintained according to Federal,
State, and Local Laws.
Secure the 3/8" (0.95 cm) swivel nut on the flexible supply tubing to the water inlet
located at the rear of the dispenser. Make sure that the flared gasket is used (tubing and
flared gasket are included with the installation kit).
IMPORTANT: When securing flare nut, use a backup wrench on the male side of the inlet fitting (unit
side) to prevent twisting of the copper tube inside the unit and/or possible damage to the water strainer/
solenoid. A water shut off outside the unit is recommended.
P
/F
RIMING
LUSHING
To properly prime the unit with water and remove air pockets in the
system, open the cabinet door and make sure that all the valve
levers are in the "Dispense" position.
Close the door and press the dispense button for a few seconds.
Repeat until a steady flow of water is observed flowing from all dis-
pense valves.
NOTE: Water splashing may occur during this purge cycle.
© 2004, IMI Cornelius Inc.

INSTALLATION

ATH
Full Water
Level
S
UPPLY
W
S
ATER
YSTEM
Cabinet
drain outlet
Water bath
overflow
- 5 -
Quest Juice Training Manual
Dispense/
Flush Lever
Publication Number: TP00968

Advertisement

Table of Contents
loading

This manual is also suitable for:

4 flavor

Table of Contents