Door Switch - 72 E Serial Number; Platform Components; Water Valve/Flow Control; Bottle Adaptor - O-Rings - Cornelius 2 Flavor Training Manual

Quest juice 2 and 4 flavor
Table of Contents

Advertisement

Quest Juice Training Manual
D
S
- 72 E S
OOR
WITCH
On or before April 1, 2004 the door switch con-
figuration will be changed to separate the reset
switch from the catch. The serial number for
this will have a prefix of 72 D for Quest 4 flavor
and 72C for Quest 2 flavor.
Kit #720911146 is available to convert field
units to this configuration. The sold-out feature
however will be inoperable with the use of this
kit.
P
C
LATFORM
OMPONENTS

Water Valve/Flow Control

The flow control is a ceramic spool and sleeve.
It must move freely to regulate the water flow
and maintain brix.
Be sure the o-ring is in place and sealing prop-
erly.

Bottle Adaptor - O-rings

When doing any assembly work on the bottle
adaptor be sure to use a small amount of lubri-
cant on each o ring This should be a food
approved non petroleum based grease.
Publication Number: TP00968
N
ERIAL
UMBER
- 30 -
Reset Switch in Top of Door
Adjustment Screw
New Door Latch
Configuration
Sleeve
Spool
Spring
© 2004, IMI Cornelius Inc.