Introduction; Preview Questions; Key Things To Know / Do - Cornelius 2 Flavor Training Manual

Quest juice 2 and 4 flavor
Table of Contents

Advertisement

Quest Juice Training Manual
P
Q
REVIEW
UESTIONS
Check your current knowledge by taking a few minutes to answer the following questions:
1. The ice bank control is adjustable?
2. The transformer does NOT control the cooling system?
3. Condenser airflow passes over the compressor first? _____ True
4. "Ratio" refers to the amount of water required to dilute one part of concentrate?
_____ True _____ False
5. O-rings may be installed dry (lubrication is not recommended)?
_____ True _____ False
K
T
T
K
EY
HINGS
O
Work Safely! Always unplug/disconnect the power to the dispenser before servicing, and get help lift-
ing the unit if it must be removed from the counter.
Make certain that the water line has adequate pressure at all times!
Learn to use a good quality volt-ohm meter. Proper electrical trouble shooting is impossible without it!
40-50 PSI dynamic water pressure measured at the dispenser inlet with 3.0 ounces a second. Water
pressure must not exceed 80 lbs static with a minimum flowing pressure of 30 PSI.
Never leave the Dispense/Flush lever in the Flush position, it can cause the pump tubing to burst.
Publication Number: TP00968

INTRODUCTION

_____ True
/ D
NOW
O
_____ False
_____ True _____ False
- 4 -
_____ False
© 2004, IMI Cornelius Inc.