Annually; Replace Pump Tubing; Removing Pump Platform(S); Replacing Pump Tubing - Cornelius 2 Flavor Training Manual

Quest juice 2 and 4 flavor
Table of Contents

Advertisement

A
NNUALLY

Replace Pump Tubing:

A replacement pump tubing kit, part#45098,
is available. The kit consists of one pre-cut
length of pump tubing, two white plastic
hose clamps, and instructions.

Removing Pump Platform(s):

1.
Remove the concentrate containers
from the dispenser and place them in a
refrigerator.
2.
Remove the cabinet shelf that the con-
centrate containers sit on.
3.
Flush the system prior to removing the
pump platform (refer to the Daily sec-
tion located at the beginning of the
Planned Maintenance Schedule).
Remove the dispense nozzles and
static mixers.
4.
Unplug the water line quick disconnect
by pressing the gray button (see Fig.
1&2).
5.
Slide the locking latch forward. Lift the
platform slightly and pull forward to
gain access to the electrical connector
(see Fig.1).
6.
Unplug the electrical connector by squeezing the locking tabs on either side and pulling out the con-
nector. Lift and remove the pump platform (see Fig.1).

Replacing Pump Tubing:

1.
Remove pump platform (refer to the Removing Pump Platform(s)
procedure located earlier in this section).
2.
Remove the two white plastic hose clamps from the pump tube con-
nections (see Fig. 1&2). Remove the concentrate delivery tubes
from the hose ends.
3.
Loosen and remove the four screws from the pump body (see fig 3).
4.
Remove the rear pump body half only to reveal the pump tube and
rollers.
5.
Remove the old pump tube from the pump body. If the roller assem-
bly comes out with the tubing, place it back into the pump housing
being sure to align the roller assembly shaft keyway to the motor
shaft so that the two interlock.
6.
Firmly press the new hose into the pump body around the
roller assembly, being sure to keep the protruding ends even
with each other.
7.
Once the tubing is in place, hold the tubing with one hand, cap-
ture the lower part of the tubing with the outer housing, then
proceed to capture the shaft of the roller assembly and push
the rear pump housing into place. Make sure to capture the
tubing within the body and not pinch it between the halves. Do
not use any tool other than your finger tips to manipulate the
tubing into the housing or you may damage the tube.
© 2004, IMI Cornelius Inc.
- 11 -
Quest Juice Training Manual
Fig. 2
Publication Number: TP00968
Fig.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

4 flavor

Table of Contents