Programmable Mirror Image (G50.1, G51.1)

Mirror image is applied to the program commands for the axes specified in the program.
Mirror image
Command format
Mirror image cancel
Command format
Mirror image setting can be applied simultaneously for the 1st to 3rd axes.
Set the mirror image axis. Omit this for axes about which a mirror image is not created.
Set the mirror image axis in workpiece coordinates.
Using G51.1 command is valid while setting a mirror image. It is regarded as an addition of
mirror axes or a change of the mirror axis coordinates.
Set the axis for canceling mirror image to cancel mirror image. Set the coordinates using
numerical values.
An alarm will occur when a mirror image is canceled for an axis where mirror image is not set.
Y
100
60
50
40
0
(1)
Original program command
(2)
When mirror axis is set for position X50.
(3)
When mirror axis is set for position X50. Y50.
(4)
When mirror axis is set for position Y50.
2004/01/22
G51.1X_Y_Z_;
G50.1X_Y_Z_;
Symmetric axis
(X=50)
(2)
(3)
0
40
50
60