Brother TC-32B Manual page 226

Table of Contents

Advertisement

Chapter12 S,T,M function
List of M code (2)
12
The code with * is already set when the power is turned on.
2004/01/22
Group
M code
M400
M400 ON (Chip shower On)
M401*
M400 OFF (Chip shower Off)
M402
M402 ON
M403*
M402 ON
M404
M404 ON
M405*
M404 OFF
M406
M406 ON
M407*
M406 OFF
M408
M408 ON (Oil hole On)
M409*
M408 OFF (Oil hole Off)
M490
Center through coolant ON
M491
Center through coolant ON
M492
Center through coolant ON
M493
Center through coolant ON
M494
Center through coolant ON
M495*
Center through coolant OFF
M496
Back washing cycle ON
M211
Workpiece counter 1set
M221*
Workpiece counter 1 cancel
M212
Workpiece counter 2set
M222*
Workpiece counter 2 cancel
M213
Workpiece counter 3 set
M223*
Workpiece counter 3 cancel
M214
Workpiece counter 4 set
M224*
Workpiece counter 4 cancel
M230*
Tool life counter set
M231
Tool life counter cancel
M800~
Signal output * for sequence
M899
controller
M900~
Extend signal output
M999
Content
simultaneous
simultaneous
simultaneous
after
before
after
before
Simultaneous
Simultaneous
Simultaneous
Simultaneous
Simultaneous
Simultaneous
Simultaneous
12 - 4
TC-32B
Operation
Modal/
order vs.
one-shot
axis feec
modal
modal
modal
modal
modal
modal
one-shot
modal
modal
modal
modal
modal
one-shot
one-shot