6.0 INSTALLATION

6.1 Kozy Heat #816-CL Co-
Linear Vent System
IMPORTANT: Proper operation of this insert requires the exhaust
and combustion air pipes to be connected to the correct collar,
on both the termination kit and the gas fireplace insert air duct.
The fireplace insert air duct exhaust collar is located on the
right side. Install termination cap with the exhaust collar on the
right side.
NOTE: The exhaust pipe will have a red marking.
IMPORTANT: Maximum horizontal vent runs of 24 in (609 mm)
require a 1 in (25mm) rise per 12 in (305 mm) run.
1.
Carefully extend the exhaust and combustion air intake pipes
to the total chimney length required. Refer to 3.2.2 Existing
Chimney Specifications on page 11.
Intake Collar (extends through bottom plate)
(A)
Exhaust Collar (extends through middle
(B)
divider plate)
Figure 6.1, #816-CL Termination Cap (your component may look different than the one shown)
14 INSTALLATION
#816-CL CO-LINEAR VENT SYSTEM
E
A
C
D
2.
Slide the combustion air intake pipe (the end without a collar)
over termination cap collar (A). Secure to termination cap (E)
with provided (3) self-tapping screws (D).
3.
Place a bead of sealant around the inner edge at the end of
the exhaust pipe (without collar / red marking) and slide onto
the corresponding labeled collar (B) on termination cap (E).
4.
Secure the exhaust pipe to termination cap (E) with the
provided (3) self-tapping screws. Apply additional sealant
around joint to ensure a proper seal.
5.
Complete vent system installation.
Sealant
(C)
Self-Tapping Screws - (3) total (2 shown)
(D)
Termination Cap
(E)
B
C