kozy heat CSK-34-R Installation And Operation Manual page 33

Direct vent gas fireplace insert
Table of Contents

Advertisement

Issue
Pilot and burner
No LP gas in tank
extinguish while in
operation
Incorrect glass assembly
installation
Incorrect vent cap installation
Vent cap blockage
Inner vent pipe leaking exhaust
gases back into the firebox
Excessive draft
Soot appears on glass
Improper rock placement
Improper venturi setting
Incorrect vent cap installation
Vent cap blockage
Flame burns blue and
Improper venturi setting
lifts off burner
Incorrect vent cap installation
Blockage or leakage of the
vent system.
No reaction to
Battery
command
remote control batteries low.
No communication between
remote control and IFC module
A maximum number of failed
ignitions or flame restorations
has been reached
Cause
Check LP (propane) tank. Refill if necessary.
Refer to 9.1 Glass Assembly on page 20.
Adjust if necessary
Remove debris if necessary
Check for leaks and repair if necessary.
An exhaust restrictor may be necessary into the exhaust pipe outlet of
the fireplace.
Refer to 9.2 #CK34-R500 Rock Kit Installation on page 21.
Venturi may need to be opened slightly to allow more air into the gas mix.
Refer to 12.2.1 Burner Venturi on page 31.
Adjust if necessary
Remove debris if necessary
Venturi may need to be opened slightly to allow more air into the gas mix.
Refer to 12.2.1 Burner Venturi on page 31.
Adjust if necessary
Check the vent pipe for leaks and the vent cap for debris. Repair vent
pipe or remove debris from vent cap if necessary.
pack
batteries
or
Replace batteries
Reprogram remote control to IFC module
Reset IFC module
Solution
TROUBLESHOOTING 33