Programming Proper Refrigerant Type Into Unit Electronics; Table 9 Displayed Error Conditions - Cornelius R-404A REFRIGERANT Service Manual

Fcb overcounter post-mix dispenser with v3+features (r-404a refrigerant)
Hide thumbs Also See for R-404A REFRIGERANT:
Table of Contents

Advertisement

MESSAGE
DISPLAYED
Motor 1
Motor 2
Motor 1
Motor 2
REFRIG
**Maximum Run Time on Compressor
SYRUP 1
SYRUP 2
CO
OUT
2
H
O
2
SENSOR 1
SENSOR 2
SENSOR 3
* The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss
has been detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and carbonator
will stop.
** 25 minutes on Standard System, 30 minutes on Remote System.
3. Press "CANCEL DEFROST" (ADVANCE) switch. The motor manufacturer's name will start blinking.
4. Press the "CANCEL DEFROST" (ADVANCE) switch again, which will change to another blinking manufac-
turer's name.
5. Keep pressing and releasing the "CANCEL DEFROST" (ADVANCE) switch until the applicable blinking
manufacturer's name appears on the message display. This indicates manufacturer's name of the No. 1
freeze cylinder beater motor (new Unit installation) or the new installed replacement motor.
6. After the applicable beater motor manufacturer's name has been selected, press "DEFROST" (SELECT)
switch which will match the beater motor to the Unit electronics. The motor manufacturer's name will no
longer be blinking.
7. Press "DEFROST" (SELECT) switch to return to "MOT_MFG1".
8. Press "CANCEL DEFROST" (ADVANCE) switch to go from "MOT_MFG1" to "MOT_MFG2" (represents No.
2 freeze cylinder beater motor) which will appear on the message display.
9. Repeat steps 2 through 6 to program in the correct beater motor manufacturer's name for No. 2 freeze
cylinder.

PROGRAMMING PROPER REFRIGERANT TYPE INTO UNIT ELECTRONICS

The Dispenser electronics must be programmed for the proper refrigeration pulse rate according to the type of
refrigerant gas that has been installed in the refrigeration system. Note Dispenser serial plate for the type of re-
frigerant gas that has been installed, then proceed as follows to program the Dispenser.
ERROR
Low Current, < 109,
Sensed on Motor One
Low Current, < 109,
Sensed on Motor Two
High Current > 255,
Sensed on Motor One
High Current > 255,
Sensed on Motor Two
Syrup Out Side One
Syrup Out Side Two
CO
Out
2
H
O Out
2
Temp Sensor Inlet One
Temp Sensor Inlet Two
Temp Sensor Outlet

TABLE 9 DISPLAYED ERROR CONDITIONS

ITEMS AFFECTED BY ERROR
BEATER
BEATER
MOTOR 1
MOTOR 2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
25
REFRIG 1
REFRIG 2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
*OFF
*OFF
OFF
OFF
OFF
OFF
OFF
OFF
312028000