Theory Of Operation; Table 2. Accessories And Tools - Cornelius R-404A REFRIGERANT Service Manual

Fcb overcounter post-mix dispenser with v3+features (r-404a refrigerant)
Hide thumbs Also See for R-404A REFRIGERANT:
Table of Contents

Advertisement

Refrigeration System:
Compressor Horsepower
Refrigerant Type And Charge
Ambient Operating Temperature
Electrical Requirements:
Operating Voltage
Operating Current
ACCESSORIES
Installation kits
Cup Holder
Cup Holder
CO
Changeover Kit
2
GENERIC FLAVOR TABS
Cola
Cherry
Orange
Grape
Lemon-Lime
Strawberry
Banana
SERVICE TOOLS
3-gallon Sanitizing Tank
Spanner Wrench, Dispensing Valve
Refractometer, 0-30 Scale
Wrench, Rear Seal Housing
Tool, Drive/Coupler Adjustment Gauge

THEORY OF OPERATION

(see Figure 2)
A CO
cylinder delivers carbon dioxide (CO
2
to the cylinder. The primary CO
inside the Unit and also to two soft drink tanks. CO
carbonator tank and also to product-blender tanks inside the Unit. CO
drink tanks through the syrup sold-out switches, through adjustable syrup flow regulators, through electrically oper-
ated syrup solenoid valves, and on to the product blender tanks. At the same time, plain water passes through the
water pressure regulator and is pumped into the carbonated water tank by the water pump and is carbonated by CO
gas pressure also entering the tank. Carbonated water is pushed by CO
tank, through adjustable carbonated water flow regulators, through electrically operated carbonated water solenoid
valves, and on to the product blender tanks. Carbonated water and syrup enter the tanks properly proportioned
(blended) for desired BRIX of dispensed product by adjustment of the syrup flow regulators.
From product blender tanks, product is pushed by the CO
cylinder is driven by an electric motor. Scraper blades, attached to the beaters, scrape product from the cylinder walls
as product enters the freeze cylinders and is frozen.
312028000
Table 1. Design Data (cont'd)

Table 2. Accessories and Tools

) gas to an adjustable primary CO
2
regulator assembly in turn delivers CO
2
is delivered from the adjustable secondary CO
2
2
regulator assembly which is attached
2
gas to adjustable secondary CO
2
gas pressure pushes syrup out of the soft
2
gas pressure from the carbonated water
2
gas into the freeze cylinders. The beater in each freeze
2
2 H.P.
See Unit Nameplate
40 F to 100 F
See Unit
Nameplate
See Unit
Nameplate
1155
511005000
511006000
511035000
1085
1086
1087
1088
1089
1090
1091
281884000
322859000
511004000
2899
3810
regulators
2
regulators to the
2
2

Advertisement

Table of Contents
loading