Watts Aerco TAG-0072 GF-146-E Operation & Maintenance Manual page 91

Natural gas and propane gas modulating condensing boilers and water heaters
Table of Contents

Advertisement

AM Series Boiler & Water Heater User Manual
CHAPTER 7: INSTALLATION – NATURAL GAS
Gas Rating Conversion of Burners 2, 3, and 4
After converting Burner 1 (Master), you must convert Burner 2, Burner 3 (if present), and
Burner 4 (if present). Refer to Figure 7-6 and perform the following steps:
1.
Turn the power OFF to the unit.
Burner 2:
Disconnect plug "B" from connector "A".
2.
Connect plug "B" to connector "C".
3.
Repeat Step 1 through Step 20 of the previous instructions "Gas Rating Conversion of
4.
Master Burner".
5.
Ensure power is still OFF to the unit.
Burner 3 (if present):
Disconnect plug "B" from connector "C".
6.
Connect plug "B" to connector "D".
7.
Repeat Step 1 through Step 20 of the previous instructions "Gas Rating Conversion of
8.
Master Burner".
9.
Ensure power is still OFF to the unit.
Burner 4 (if present):
Disconnect plug "B" from connector "D".
10.
Connect plug "B" to connector "E".
11.
Repeat Step 1 through Step 20 of the previous instructions "Gas Rating Conversion of
12.
Master Burner".
After converting all burners:
Connect plug "B" to plug "A".
13.
14.
Check the inlet gas pressure of the unit, per Section 8.6.
15.
Attach to the front of the heater the appropriate conversion label, found in the conversion kit
stating the new type of gas adjustment of the heater as follow:
a) Apply the label in Figure 7-7 if the heater has been converted to PROPANE GAS.
b) Apply the label in Figure 7-8 if the heater has been converted to NATURAL GAS.
OMM-0100_E • GF-146 • 11/15/2019
Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST
Page 91 of 170