DISPLAYING ''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) ONTO MESSAGE
DISPLAY
(see Tables 4 and 8).
1. ''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) may be displayed on message display as
follows:
2. Refer to PROGRAMMING MAIN MENU SELECTION ONTO MESSAGE DISPLAY and bring up the word
''CLOCK'' on message display.
3. Repeatedly press and release ''CANCEL DEFROST'' (ADVANCE) switch to advance through main menu
until ''TOTALS'' menu appears on message display. Press ''DEFROST'' (SELECT) switch to lock
''TOTALS'' menu in place. The word ''COMP HRS'' will appear on message display.
4. Press and hold ''DEFROST'' (SELECT) switch. Compressor run hours will appear on message display.
5. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''COMP CYC'' on message
display.
6. Press and hold ''DEFROST'' (SELECT) switch. Compressor cycles x 100 will appear on message display.
7. Use CANCEL DEFROST (ADVANCE) switch to advance through remaining ''TOTALS'' (DISPLAYED
CYCLES AND HOURS TOTAL MENU) see Table 8. Press ''DEFROST'' (SELECT) switch to obtain
message display readings of the individual menu selections.
8. Press ''ERROR RESET'' switch two times to exit from MENU SELECTIONS.

DISPLAYED ERROR CONDITIONS

Displayed error conditions, associated errors, and items affected by the errors are found in Table 9 DISPLAYED
ERROR CONDITIONS.

CLEANING AND SANITIZING

DAILY CLEANING OF UNIT

Daily, or more often if necessary, wash all external surfaces of Unit with a mild soap solution. Rinse with clean
water, then wipe dry with a clean soft cloth. DO NOT USE ABRASIVE-TYPE CLEANERS. Remove and wash
drip tray in mild soap solution, rinse with clean water, then install drip tray on Unit.

SANITIZING SYRUP SYSTEMS

NOTE: The Unit should be sanitized every 90-days following Sanitizer Manufacturer's recommendation.
Use Chlor-Tergent (Oakite Products, Inc.) or equivalent sanitizer.
The Unit should be sanitized every 90-days and before and after storage periods following parent company
requirements and sanitizer manufacturer's recommendations. One or both syrup systems may be sanitized at
one time for routine 90--days sanitizing requirements. The following sanitizing instructions use No. 1 syrup
system as an example. No. 2 syrup systems sanitizing instructions are identical to No. 1 syrup system with
exception of using applicable system switches. Proceed as follows:
1. Press ''OFF 2'' switch to stop beater motor and refrigeration in No. 2 freeze cylinder which is not to be
defrosted. ''OFF 2'' fault message will appear on message display.
2. Press ''DEFROST'' switch to start defrost cycle on No. 1 freeze cylinder. ''DEFROST 1'' message will
appear on message display as long as defrost cycle is in progress.
3. Immediately press ''AUTO 2'' control switch to restart beater in No. 2 freeze cylinder. Refrigeration in No. 2
cylinder will not be operating.
45