Step
7

Manual Diagnostic Menu

The Manual Diagnostic menu, shown in Figure 52, is used for troubleshooting and testing the system on a component basis. It
allows the service technician to turn individual components of the system on and off for troubleshooting purposes. Pressing
the BACK button returns the display to the Main menu and turns off all the active loads.
This screen should only be used by qualified technicians to troubleshoot the system.
The items shown in Table 49 are for the first barrel in the unit only. The list includes additional components with their related
barrel number, i.e. Hot Gas Sol #2, etc.
!
CAUTION:
The compressor can suffer damage if it is allowed to run without either a hot gas defrost or liquid line solenoid open. The
software is designed to turn on the hot gas solenoid for a barrel to prevent damage from occurring.
Display
POS LIGHTING
COMPRESSOR #1
HOT GAS SOL #1
PRODUCT SOL #1
CO2 VALVE #1
LLS VALVE #1
BRL MOTOR #1
To move between one set of barrel parameters to the next, press the Right or Left arrow keys. This moves the highlight to the
first entry of the second barrel, etc.

Totals Menu

The Totals screen (Figure 53) shows the cumulative run time of the system, a component of the system or an error. Some
individual items may be reset, where available, by highlighting the item and pressing the RESET button. The RESET button is
only displayed for items that may be reset, such as hours since the motor seal was changed or the number of compressor
© 2022, Marmon Foodservice Technologies Inc.
Action
Repeat the Purge procedure in Table 45 to empty the
Complete the procedure
barrel.
POS LIGHTING
MANUAL
COMPRESSOR #1
DIAG
HOT GAS SOL #1
PRODUCT SOL #1
12:51P
CO2 VALVE #1
MAR 04
LLS VALVE #1
BACK
ON
Figure 52. Manual Diagnostic Screen
This selection turns the Point-Of-Sale lighting on and off
This selection turns the compressor on and off
This selection opens and closes the hot gas solenoid for barrel 1
This selection opens and closes the product solenoids and valves
for barrel 1
This selection opens and closes the CO
barrel 1
This selection opens and closes the Liquid Line solenoid and valve
for barrel 1
This selection turns the barrel 1 motor on and off
- 67 -
Viper Installation, Service & Decommissioning Manual
Table 48.
Procedure
OFF
OFF
ON
OFF
OFF
OFF