Installation - ADJ ENCORE LP18IP User Manual

Hide thumbs Also See for ENCORE LP18IP:
Table of Contents

Advertisement

I N S TA L L AT I O N
FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or
pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.
USE CAUTION WHEN POWER LINKING FIXTURES OF OTHER MODEL TYPES, AS
THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE
MAX POWER OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS
MINIMUM DISTANCE TO OBJECTS/SURFACES IS 6.6 FEET (2 METERS).
MINIMUM DISTANCE OF FLAMMABLE MATERIALS FROM THE SURFACE IS 1.6
FEET (0.5 METER)
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and
construction codes and regulations.
Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing
the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine
if the metal truss/structure or surface is properly certified to safely hold the combined weight of the
fixture(s), clamps, cables, and accessories.
Maximum fixture ambient operating temperature is 113°F (45°C). Do not use operate the fixture
when ambient temperature exceeds this value!
Fixture(s) should be installed in areas outside walking paths, seating areas, or areas were
unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment, such as
an appropriately rated safety cable.
Allow approximately 60 minutes for the fixture to cool down before servicing.
IP RATING
This device is IP65 rated. This means that the unit is dust-tight, and protected against low-
pressure jets of water from any direction
RIGGING
Overhead rigging requires extensive experience, including calculating working load limits,
knowledge about installation materials being used, and periodic safety inspection of all
installation material and the fixture, among other skills. If you lack these qualifications, do not
attempt the installation yourself. Improper installation can result in bodily injury.