Summary of Contents for ADJ ENCORE LP12Z IP

  • Page 1 ENCORE LP12Z IP User Manual...
  • Page 2 ©2023 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying prod- uct names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    T A B L E O F C O N T E N T S Introduction Limited Warranty (USA Only) Warranty Registration | Features IP65 Rated Safety Precautions Overview Installation Accessory Installation Wireless Setup Remote Device Management (RDM) Control Panel System Menu Operational Modes DMX Set Up...
  • Page 4: Introduction

    I N T R O D U C T I O N Unpacking: Thank you for purchasing the Encore LP12Z IP by ADJ Products, LLC. Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the ship- ping carton for damage that may have occurred during shipping.
  • Page 5: Limited Warranty (Usa Only)

    The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
  • Page 6: Warranty Registration | Features

    W A R R A N T Y R E G I S T R A T I O N Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number.
  • Page 7: Ip65 Rated

    10,000-hours. This is a prophylactic measure intended to keep the unit running as cool as possible, insuring proper function of all internal components. A complete service breakdown is available, please contact service@adj.com for any needed parts or manuals.
  • Page 8: Safety Precautions

    S A F E T Y P R E C A U T I O N S PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED. THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY.
  • Page 9: Overview

    O V E R V I E W Safety Cable Loop Mounting Yoke Knob Mounting Yoke Display Screen Down Button Mode Button Button Enter Button Valve Power Power...
  • Page 10: Installation

    I N S T A L L A T I O N DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO! Fixture MUST be installed following all local, national, and country commercial electrical and construc- tion codes and regulations. When installing the unit, the trussing or area of installation must be able to hold 10 times the weight of the unit and any attached accessories without any deformation.
  • Page 11 I N S T A L L A T I O N CLAMP MOUNTING This fixture features two mounting holes for the attachment of an Omega bracket, which are located on the adjustable mounting yoke. Insert the Omega bracket’s twist lock fasteners into these two mounting holes, then twist to secure in place.
  • Page 12 I N S T A L L A T I O N STAND MOUNTING This unit can also be installed atop a tripod stand. Simply secure the Omega bracket to the bottom face of the device, then insert the threaded bolt on the top of the tripod stand through the hole in the Omega bracket.
  • Page 13 LEDs. This issue is not specific only to ADJ lighting fixtures, but rather it is a common issue with lighting fix- tures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can reduce the risk of potential damage.
  • Page 14 I N S T A L L A T I O N NOTICE: The maximum ambient operational temperature for this lighting fixture is 113˚ F (45˚ C). Do not place this lighting fixture in an enviroment where the temperatures exceed this value. This will allow the fixture to run at its best and help prolong the fixture life.
  • Page 15: Accessory Installation

    A C C E S S O R Y I N S T A L L A T I O N GEL FRAME AND BARN DOORS Available accessories include a gel frame and a set of barndoors, both of which can easily be installed using the fixture’s detachable accessory mounting slot.
  • Page 16 A C C E S S O R Y I N S T A L L A T I O N GEL FRAME AND BARN DOORS 5. Align the semi-circular slots on the front of the 6. Flip the latch closed to secure the gel barndoors with the two screw holes located on frame and barndoors in place.
  • Page 17: Wireless Setup

    W I R E L E S S S E T U P To set up wireless control, follow the steps below: 1. Navigate to Personality > Wireless Settings in the system menu. Press ENTER to select this menu. 2. Use UP and DOWN to scroll to “Wireless Settings” and press ENTER. Use UP and DOWN to scroll to the “On”...
  • Page 18: Remote Device Management (Rdm)

    R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
  • Page 19: Control Panel

    C O N T R O L P A N E L This unit features a display screen with a 4-button control pad, which can be used to easily adjust any device settings. Pressing the MODE button will cycle through the various Main Menu options. When the desired Main Menu option is displayed on the screen, press the ENTER button to enter the sub-menu, then use the UP and DOWN buttons to scroll through sub-menu options.
  • Page 20: System Menu

    S Y S T E M M E N U Set DMX ad- 001 - 512 Address dress 10Ch Select DMX Ch Mode channel mode 12Ch 15Ch 18Ch Unit holds last DMX values Hold received when signal is lost DMX SET Unit takes all channels to Blackout...
  • Page 21 S Y S T E M M E N U Zoom adjust- Mode 1 ment moves quickly Zoom Mode Slow zoom Mode 2 speed w/ minim- mal noise Yes / No Zoom Reset Reset zoom Standard Stage Select dim mode Archi Dim Mode Theatre...
  • Page 22 S Y S T E M M E N U 000 - 255 Shutter 000 - 255 Mastr Dim Manual mode 000 - 255 Zoom Line settings; please MANUAL 000 - 255 Zoom Pres note that Color (continued) Macros will 000 - 255 Auto Prog override manual...
  • Page 23: Operational Modes

    O P E R A T I O N M O D E S This device features 4 different operation modes, plus a primary/secondary setting, all of which can be selected from the main system menu. These are easily configured and operated from the display screen and its control buttons.
  • Page 24 O P E R A T I O N M O D E S DMX CONTROL MODE: Control the unit using a DMX controller. 1. Use a DMX cable to connect the output port of your DMX controller to the DMX Input port of your first fixture.
  • Page 25: Dmx Set Up

    D M X S E T U P DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of commu- nication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN”...
  • Page 26 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will reduce the risk of erratic behavior. DMX ADDRESSING.
  • Page 27: Dmx Traits

    D M X T R A I T S CHANNEL FUNCTION VALUES 10Ch 12Ch 15Ch 16Ch Red, 0% to 100% 000 - 255 Red Fine 000 - 255 Green, 0% to 100% 000 - 255 Green Fine 000 - 255 Blue, 0% to 100% 000 - 255 Blue Fine...
  • Page 28 D M X T R A I T S CHANNEL FUNCTION VALUES 10Ch 12Ch 15Ch 18Ch Auto Programs 000 - 031 032 - 063 Auto Program 1 064 - 095 Auto Program 2 096 - 127 Auto Program 3 128 - 159 Auto Program 4 160 - 191 Auto Program 5...
  • Page 29 D M X T R A I T S CHANNEL FUNCTION VALUES 10Ch 12Ch 15Ch 18Ch Special Functions (continued) 151 - 165 5000 Hz 166 - 180 10000 Hz 181 - 195 15000 Hz 196 - 210 20000 Hz 211 - 225 25000 Hz 226 - 229 Enable Zoom Mode 1 (hold 3s)
  • Page 30: Color Macros Chart

    C O L O R M A C R O S C H A R T COLOR MACRO DMX VALUES GREEN BLUE LIME NUMBER 001 - 004 005 - 008 009 - 012 013 - 016 017 - 020 021 - 024 025 - 028 029 - 032 033 - 036...
  • Page 31 C O L O R M A C R O S C H A R T COLOR MACRO DMX VALUES GREEN BLUE LIME NUMBER 141 - 144 145 - 148 149 - 152 153 - 156 157 - 160 161 - 164 165 - 168 169 - 172 173 - 176...
  • Page 32: Dim Speeds

    D I M S P E E D S DMX VALUES DELAY TIME 0.1 sec 0.2 sec 0.3 sec 0.4 sec 0.5 sec 0.6 sec 0.7 sec 0.8 sec 0.9 sec 1.0 sec 1.5 sec 2.0 sec 3.0 sec 4.0 sec 5.0 sec 6.0 sec 7.0 sec...
  • Page 33: Dim Modes

    D I M M O D E S DIMMER 100% Time (ms) Rise Time Down Time 0 Sec 0 sec Fade Time 1 sec Fade Time Dimming Curve Ramp Effect Rise Time (ms) Down Time (ms) Rise Time (ms) Down Time (ms) Standard (default) Stage 1100...
  • Page 34: Primary-Secondary Set Up | Multi Unit Power Linking

    P R I M A R Y - S E C O N D A R Y S E T U P This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs.
  • Page 35: Maintenance Guidelines

    Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized ADJ service technician. Should you need any spare parts, please order genuine parts from your local ADJ dealer.
  • Page 36: Torque Settings For Screws

    Following any maintenance or repair procedure that requires the opening of the fixture casing, the casing must be re-installed using a torque driver and torqued to the specified settings below. The re-assembled fixture should also be tested using an ADJ Hydro IP Tester in order to ensure that the fixture’s IP rating remains valid.
  • Page 37 CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE USING THE IP TESTER. CONTACT ADJ SERVICE FOR MORE DETAILS. CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS...
  • Page 38: Dimensional Drawings

    D I M E N S I O N A L D R A W I N G S FIXTURE ONLY 12.4 in (316mm) 13.7 in (347mm) 2.3 in 1.9 in 12.4 in (316mm) (58mm) (47mm) 6.3 in 10.2 in (259mm) (159mm) 10.4 in (264mm) Drawings not shown to scale.
  • Page 39 D I M E N S I O N A L D R A W I N G S GEL FRAME 9.7 in (246mm) 0.1 in (2mm) GEL FRAME HOLDER 10.1 in (256mm) 8.9 in (225mm) 5.7 in (144mm) 0.2 in (6mm) 0.5 in (12mm)
  • Page 40 D I M E N S I O N A L D R A W I N G S BARNDOOR 0.2 in 13.4 in (340mm) (6mm) 1.5 in (39mm)
  • Page 41: Specifications

    S P E C I F I C A T I O N S SOURCE: CONSTRUCTION: • Light Source: 12 x 20-Watt Quad RGBL LEDs • IP65 Rated: Ingress Protection against liquid, (4-IN-1: Red, Green, Blue & Lime) snow, dust and sand •...
  • Page 42: Optional Accessories | Error Codes

    O P T I O N A L A C C E S S O R I E S ORDER CODE (US) ORDER CODE (EU) DESCRIPTION ELP18L100 1226100403 100° frost filter ELP18L60 1226100402 60° frost filter ELP18L30X60 1226100405 30x60° frost filter ELP18L1X40 1226100404 1x40°...
  • Page 43 This page intentionally left blank.

This manual is also suitable for:

Enc395

Table of Contents