Other Service Work; Aligning The V-Port Plug - Samson 3241-1-Gas Mounting And Operating Instructions

Automatic shut-off valves for gases
Hide thumbs Also See for 3241-1-Gas:
Table of Contents

Advertisement

A7
A26/27
9
10
2
8
15
14
Strainer

7.2 Other service work

NOTICE
!
Risk of control valve damage due to incorrect
service or repair.
To replace seat and plug, packing or bellows
seal, contact SAMSON's After‑sales Service.
EB 8020-1 EN
Pilot valve
P st
42
37
22
17
5
4
1
Fig. 9: Type 3241‑1‑Gas Automatic

7.3 Aligning the V-port plug

Each V‑port plug has three V‑shaped ports.
Depending on the valve size, the size of the
symmetrically arranged V‑shaped ports var‑
ies. The process medium in the valve flows
through the V‑shaped ports as soon as the
plug is lifted out of the seat (i.e. the valve
opens).
1. Before mounting the actuator, determine
which V‑shaped port is uncovered first
when the plug is lifted out of the seat.
1
Body
2
Flange
4
Seat
5
Plug (with plug stem)
8
Threaded bushing
(packing nut)
9
Stem connector nut
10
Lock nut
14
Body nut
15
Packing
17
Body gasket
22
Bellows seal
37
Plug stem with metal
bellows
42
Test connection
A7
Actuator stem
A26/27 Stem connector clamps
Shut‑off Valve